Download MDT-DCS CANopen Module, user manual

Transcript
v2.7 19-Aug-2011
MDT-DCS CANopen module
The module has 2 CAN-bus connectors to enable easy daisy chaining of multiple modules
on one CAN-bus. The last module on the bus must be equipped with a termination resistor
(120 Ω, or 180 Ω in the Y-shaped bus layout used for MDT CAN-buses), using a special cable-less connector with the terminator installed inside the connector housing, which is then
plugged into the empty CAN-connector of the last module on the bus.
2.2
ELMB / MDT-DCS Interface and ELMB Jumpers
This section describes how the ELMB board inside the MDT-DCS module interfaces hardware-wise to the rest of the system, and explains the function of the jumpers and switches present on the ELMB. It is given here for reference only.
Table 7 shows the mapping of I/O-pin-to-function of the ATmega128 microcontroller on the
ELMB inside the MDT-DCS module:
•
•
•
•
•
ADC_xxx is the SPI interface for the ELMB on-board ADC with monitors up to 64
channels of MDT-chamber T-sensors (NTCs).
AUX_IO is the spare interface with 5 digital I/O lines (function to be defined; not
yet under control of the firmware); present on module connector labelled
SPI-AUX.
B_xxx
is the SPI interface including two chip-select lines (B_CSx) and 2 lines
carrying the 1-Wire protocol for the Identification-chips (B_IDx), for up
to 2 B-sensor modules on the MDT-chamber; present on module connectors labelled B-sensor 0 and B-sensor 1.
CSM_xxx is the SPI interface to the CSM front-end electronics ELMB-ADC which
monitors up to 64 parameters; present on module connector labelled
CSM-ADC.
DIGIOx are digital in- and outputs from/to the CSM front-end electronics (exact
function still to be defined; the firmware assumes a default configuration
of inputs and outputs, but this can be changed; see Object Dictionary);
present on module connectors labelled JTAG and CSM-ADC.
10