Download Cycle Analyst V3.0 Unofficial User Guide

Transcript
Unofficial CA V3 User Guide
6.9
Serial Data Port
1.
Encoding/Signal Levels: The Tx/Rx serial ports operate at 9600 baud with 8 bits, 1 Stop bit, and no parity
at 0v/+5v TTL levels.
2.
Live Data Stream: In normal operating mode a serial data stream is transmitted from the serial port. This
stream may be captured by a Cycle Analogger or similar device (there is no handshake) and contains
TAB-separated data as described in the following table. The data rows are sent periodically at the rate
configured by Pref->RS232.
Col
1
2
3
4
5
6
7
8
9
10
11
12
13
Headin
g
Ah
V
A
S
D
Deg
RPM
HW
Nm
ThI
ThO
Acc
Lim
Description
Amp hour
Voltage
Amperes
Speed
Distance
Temperature degC
PAS RPM
Human Watts
Thun Newton-meters
Throttle In Voltage
Throttle Out Voltage
Acceleration
Limit Flag Characters
3.
Interface Cable: The standard Grin Tech CA V3 programming cable (pn: CA3-USB) is an FTDI
TTL-232R-5V-AJ and is best ordered with the CA V3 to facilitate firmware updates.
See the Grin Tech site for USB->TTL converter cable ordering and device driver download information.
4.
External Memory Access: Using the bootloader, all of the V3 EEPROM may be accessed externally via the
serial interface. This supports loading new firmware as well as external inspection and configuration of Setup
parameters. See these posts [1, 2] for bootloader protocol and EEPROM parameter layout. For operation of
the updater application see 'Update CA with Most Recent Firmware'.
2013-03-14 1200 (B22)
31/39