Simrad AI80 Installation Manual
If the system outputs an alarm, the alarm condition can be read from
the display.
Power supply failure
If the unit periodically restarts approximately every one minute, this
could indicate a power supply failure.
Use the following procedure to check for power failure:
1. Check that external power has been connected to the rear
connectors.
2. Verify that supplied power is in accordance with technical power
specifications, page 8.
3. Verify that power cable dimensions are minimum 2.5 mm2.
GPS and VHF antenna cable connections
Typical problems when no GPS signal is received are that the GPS
antenna cable and/or connectors are damaged, or that the cables are
not properly connected. In order to check for antenna cable problems,
ensure that the GPS antenna is disconnected. The Ohm reading
between the centre and the screen should normally be infinite if there
is no short-circuit in the cable. Make a short-circuit in the opposite
end of the cable and measure the resistance. Now the reading should
be approximately 0 Ohm.
GPS and VHF antenna malfunction
Disconnect the GPS antenna cable at the rear side of the Mobile Unit.
Measure the resistance between the centre pin and shield in the cable
(with the antenna connected). The GPS antenna does not have a
defined resistance that can be measured. Therefore, before
measurements can be carried out, the antenna end of the cable needs
to be short-circuited. Measure between centre conductor and shield.
Resistance should be close to 0 Ohm.
Caution!
Switch off the power before disconnecting the antenna!
GPS receiver failure
During normal operation the GPS LED blinks green once each
second. If the GPS LED on the front of the unit blinks amber, the
AI80 system computes no position data, the GPS receiver inside the
Mobile Unit should be checked.
92