Download QC-CALC User`s Manual
Transcript
PopUp Menu - Reference Section 11. PopUp Menu (Right Click on Any Plot) As with most Windows programs, the right mouse button usually has hidden options. If you Right click any plot on the QC-CALC Real-Time screen, a special menu pops up with a variety of options. This type of interface allows you to select the plot before the menu is activated. 11.1 Print Report When a report is printed under the File – Print Report menu, the details of that session are saved on your computer. When you pick this right-mouse click menu option the saved configuration is read and the report is printed again. The difference between the old and new report is the data points that are actually printed. For example, if you chose to print the last 5 parts using the Five Piece First Article Report, every time you click this menu, you’ll get the last 5 parts printed. This may make more sense when you consider the QC-CALC live plots are constantly having new data added to them. In other words, the last 5 parts is not going to produce the same report since the data is changing through time. Several of the reports can be printed from the current cursor position. For example, the First Article Reports are based from the current position. This means if you want to print a First Article Report for data collected days ago, simply scroll the live plots back to the data of interest, right click the point, and select Print Report. 11.2 Calculate Limits When this menu is checked QC-Calc will recalculate new control and tolerance limits based on the data shown on the plot. The items to calculate are set in Tools – Options – Statistical Settings – Items to Calculate and include the Control Limits, Specification Limits, Mean, Sigma Zones, and Nominal. See page 126 for more details. 11.3 Save Calculated Limits If you want to save the limits that were calculated by clicking the Calculate Limits menu you can right-click the same plot again and choose Save Calculated Limits. You are prompted with an Are You Sure? dialog box since the database values will be overwritten with these new values. If you do not save these new limits you can restore your previous values by right-clicking on the plot, select Calculate Limits and your original values reappear. 11.4 Prevent Tolerance Update from Machine A special feature of QC-CALC is the ability to block or prevent some nominals from being updated even though Update Nominals is set to ALWAYS. This option allows you to get very specific as to how and what is synchronized in the database with your part program. Let’s say your part program is changing due to engineering changes so you set the Update Nominals to ALWAYS to stay synchronized. However, you do not QC-CALC Real-Time® Page - 153