Download QC-CALC User`s Manual

Transcript
PopUp Menu - Reference Section
11. PopUp Menu (Right Click on Any Plot)
As with most Windows programs, the right mouse
button usually has hidden options. If you Right click
any plot on the QC-CALC Real-Time screen, a
special menu pops up with a variety of options.
This type of interface allows you to select the plot
before the menu is activated.
11.1 Print Report
When a report is printed under the File – Print
Report menu, the details of that session are saved
on your computer. When you pick this right-mouse
click menu option the saved configuration is read
and the report is printed again. The difference
between the old and new report is the data points
that are actually printed. For example, if you chose
to print the last 5 parts using the Five Piece First
Article Report, every time you click this menu,
you’ll get the last 5 parts printed. This may make
more sense when you consider the QC-CALC live
plots are constantly having new data added to
them. In other words, the last 5 parts is not going to
produce the same report since the data is changing through time.
Several of the reports can be printed from the current cursor position. For
example, the First Article Reports are based from the current position. This
means if you want to print a First Article Report for data collected days ago,
simply scroll the live plots back to the data of interest, right click the point, and
select Print Report.
11.2 Calculate Limits
When this menu is checked QC-Calc will recalculate new control and tolerance
limits based on the data shown on the plot. The items to calculate are set in
Tools – Options – Statistical Settings – Items to Calculate and include the
Control Limits, Specification Limits, Mean, Sigma Zones, and Nominal. See page
126 for more details.
11.3 Save Calculated Limits
If you want to save the limits that were calculated by clicking the Calculate Limits
menu you can right-click the same plot again and choose Save Calculated
Limits. You are prompted with an Are You Sure? dialog box since the database
values will be overwritten with these new values. If you do not save these new
limits you can restore your previous values by right-clicking on the plot, select
Calculate Limits and your original values reappear.
11.4 Prevent Tolerance Update from Machine
A special feature of QC-CALC is the ability to block or prevent some nominals
from being updated even though Update Nominals is set to ALWAYS. This
option allows you to get very specific as to how and what is synchronized in the
database with your part program.
Let’s say your part program is changing due to engineering changes so you set
the Update Nominals to ALWAYS to stay synchronized. However, you do not
QC-CALC Real-Time®
Page - 153