Download Paromax inc.

Transcript
Installation
Unit location
For optimum benefit with your appliance, speak to an authorized Paromax Dealer concerning the unit location.
The location for your appliance can be a factor in how it will perform. Choose an interior location where the pellet
vent will not be affected by any external interference, ex; trees, bushes, walls or fencing (refer to “Vent Termination
Requirements” section at page 10). Install the unit according to recommendations made on “clearances” section at
page 10 or according to the safety label fixed on the unit.
Always use a pellet vent double wall type PL with a inside diameter of 3” / 7.6 cm or 4” / 10.2 cm maximum. You
can pass the pellet vent system thru the wall behind the unit. Paromax recommend to use rigid pellet vent pipe up
thru the existing chimney.
Ensure that all clearances to combustibles are met as per the safety label and the diagrams on “Clearances” section at page 9.
This appliance may need outside air if there is a negative pressure within the room. Make sure the outside air supply for the unit does not come from a garage, an attic or any restricted non-ventilated space.
The floor mat under the stove must be of non-combustible material, i.e. cement, ceramics, etc... and must extend
6” or 15.2 cm for the sides and front. Refer to the diagrams on “Clearances” section at page 9.
Requirement: Avoid any PL pellet vent quick connection (twist lock) in the attic or roof space, closet or similar concealed space, floor or ceiling. Do not use different brand or models of vent pipe on the same vent pipe installation.
WARNING: DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM
OF THIS UNIT. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE. DO NOT CONNECT TO ANY DISTRIBUTION DUCT OR SYSTEM.
Pellet vent size (PL)
IMPORTANT: Always use a double wall 3” / 7.6 cm or 4” / 10.2 cm PL type pellet vent approved for venting wood
pellets fuel or agriculture fuel. A tight seal (silicone or aluminum tape) is recommended on each section of the
pellet vent to prevent smoke leakage and odors. The pipe connecting to the unit and the outer wall joints located
between the pipes also need to be sealed with high temperature silicone or aluminum tape. The maximum pellet
vent height is 35 feet or 10.6 meter. Use a wall thimble for flammable wall or collar for cement wall. Seal the exterior pellet vent with silicone to create a vapor barrier.
It is not recommended to seal the inner walls joints already containing a pre-installed silicone or rubber
sealant by the manufacturer of the pellet vent. Do not use a perforated outer wall pellet vent flue channeling fresh air to the burner.
WARNING: DO NOT INSTALL IN SLEEPING ROOM
CAUTION: THE STRUCTURAL INTEGRITY OF THE MANUFACTURED
HOME FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED
6