Table 12-1
Data Interface Unit factory default
Data Interface Unit Type
Default Link Capacity
4E1 BNC
4E1
7 MHz
E3 + 16E1
E3+1E1
28 MHz
4 x LAN + 4 E1
10/100 BaseT + 4 E1
28 MHz
DS3 + 16DS1
DS3 + 4DS1
24 MHz
10/100 BaseT + 4 DS1
10/100 BaseT + 4 DS1
50 MHz
Table 12-2
Control Panel parameter
Default Channel Spacing
Codan 8800 series Terminal Factory Default
Default Parameter
Frequency (Ch#)
Middle frequency (Depends on the ODU type)
Tx Power
Max power and Tx range (Depends on the ODU maximum power)
Link ID
1
ATPC Control
Disabled
RSL Optimal Val
-45
RSL Upper Thr
-40
RSL Lower Thr.
-50
ETH IP Mask
255.255.255.0
ETH IP
192.168.X.1
ETH IP RIP
Disabled
NMS-In IP
Determined by the system
NMS-In Dest IP
10.1.1.1
NMS-Out IP
NMS-In IP + 1
NMS-Out Dest IP
NMS-In Dest IP + 1
LINK IP
NMS-Out IP + 1 (or NMS-In + 2)
NMS-IN & OUT
Baud Rate
Flow Control
Data Bits
Stop Bits
Parity
19200
NONE
8 Bits
1 Stop Bit
None