Download User Manual go2ANALYSE 2.2 - HIK

Transcript
Using the option  Type S in the Recover dialogue box, the output bit is 0 if there is a change between
two successive bits, otherwise it is 1.
Note: The bit rate after application of the function is divided by 2.
The logical table for the two BIPH types is:
Input Bits
Output Bit
BIPH-M
Output Bit
BIPH-S
Bit 1
Bit 2
Bit
Bit
0
0
0
1
0
1
1
0
1
0
1
0
1
1
0
1
Table 29: BIPH-M and BIPH-S Decoding
Recover Manchester Code: BIPH-L
The original bitstream is recovered from a Manchester-coded stream by calculating the value of the original bit from two successive bits, thus recovering one output bit from two input bits.
The Manchester Code is sometimes also known as BIPH-L code.
Note: The bit rate after application of the function is divided by 2.
The logical table for Manchester is:
Input Bits
Output Bit
Bit 1
Bit 2
Bit
0
0
0
0
1
1
1
0
0
1
1
1
Table 30: BIPH-L Decoding
Comparison
The next figure illustrates the recovering functions applied. The first line shows the output bits, the lines
below show the input stream before the recovering function has been applied to the stream.
User Manual go2ANALYSE 2.2
User Functions  65