Download 4 - Process Centre Of Excellence.

Transcript
Transducer Block (TB) Menu Structure
Parameter Label
Menu Structure
Processor Alert
TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Processor Alert
Processor Alert Enable
TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Processor Alert Enable
Program Memory Alert
TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Program Memory Alert
Program Memory Alert
Enable
TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Program Memory Alert Enable
Program Memory Manual
Recovery
TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Program Memory Manual
Recovery
Program Memory Shutdown
TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Program Memory Shutdown
Protection
TB > Device Variables > Protection
Proximity Hi Alert
TB > Configure/Setup > Detailed Setup > Alerts > Prox Alerts > Proximity > Proximity Hi Alert
Proximity Hi Alert Enable
TB > Configure/Setup > Detailed Setup > Alerts > Prox Alerts > Proximity > Proximity Hi Alert Enable
Proximity Hi Hi Alert
TB > Configure/Setup > Detailed Setup > Alerts > Prox Alerts > Proximity > Proximity Hi Hi Alert
Proximity Hi Hi Alert Enable
TB > Configure/Setup > Detailed Setup > Alerts > Prox Alerts > Proximity > Proximity Hi Hi Alert Enable
Proximity Lo Alert
TB > Configure/Setup > Detailed Setup > Alerts > Prox Alerts > Proximity > Proximity Lo Alert
Proximity Lo Alert Enable
TB > Configure/Setup > Detailed Setup > Alerts > Prox Alerts > Proximity > Proximity Lo Alert Enable
Proximity Lo Lo Alert
TB > Configure/Setup > Detailed Setup > Alerts > Prox Alerts > Proximity > Proximity Lo Lo Alert
Proximity Lo Lo Alert Enable
TB > Configure/Setup > Detailed Setup > Alerts > Prox Alerts > Proximity > Proximity Lo Lo Alert Enable
Push Down To
TB > Configure/Setup > Detailed Setup > Valve and Actuator > Trim > Push Down To
Rated Travel
TB > Configure/Setup > Detailed Setup > Valve and Actuator > Valve > Rated Travel
Relay Type
TB > Configure/Setup > Detailed Setup > Instrument > Relay Type
Seat Type
TB > Configure/Setup > Detailed Setup > Valve and Actuator > Trim > Seat Type
Setpoint
TB > Device Variables > AO Control-Pre-Char > Setpoint
Setpoint Status
TB > Device Variables > AO Control-Pre-Char > Setpoint Status
Setpoint(D)
TB > Device Variables > DO Control > Setpoint(D)
Shaft Stem Diameter
TB > Configure/Setup > Detailed Setup > Valve and Actuator > Valve > Shaft Stem Diameter
Simulate Active
TB > Device Diagnostics > Status > Block Error > Block Error.Simulate Active
Simulate Jumper ON
TB > Device Diagnostics > Status > Self Test Status > Simulate Jumper ON
Spring Rate
TB > Configure/Setup > Detailed Setup > Valve and Actuator > Actuator > Spring Rate
Spring Rate Units
TB > Configure/Setup > Detailed Setup > Instrument > Spring Rate Units
Static Memory Alert
TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Static Memory Alert
Static Memory Alert Enable
TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Static Memory Alert Enable
Static Memory Manual
Recovery
TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Static Memory Manual Recovery
Static Memory Shutdown
TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Static Memory Shutdown
Stroke Time Close
TB > Configure/Setup > Detailed Setup > Valve and Actuator > Reference > Stroke Time Close
Stroke Time Open
TB > Configure/Setup > Detailed Setup > Valve and Actuator > Reference > Stroke Time Open
Supply
TB > Configure/Setup > Detailed Setup > Alerts > Environment Alerts > Supply Pressure > Supply
TB > Device Variables > Pressures > Supply
Supply Pressure Hi Alert
TB > Configure/Setup > Detailed Setup > Alerts > Environment Alerts > Supply Pressure > Supply Pressure Hi Alert
Supply Pressure Hi Alert
Enable
TB > Configure/Setup > Detailed Setup > Alerts > Environment Alerts > Supply Pressure > Supply Pressure Hi Alert
Enable
Supply Pressure Hi Alert
Point
TB > Configure/Setup > Detailed Setup > Alerts > Environment Alerts > Supply Pressure > Supply Pressure Hi Alert
Point
Supply Pressure Lo Alert
TB > Configure/Setup > Detailed Setup > Alerts > Environment Alerts > Supply Pressure > Supply Pressure Lo Alert
Supply Pressure Lo Alert
Enable
TB > Configure/Setup > Detailed Setup > Alerts > Environment Alerts > Supply Pressure > Supply Pressure Lo Alert
Enable
Supply Pressure Lo Alert
Point
TB > Configure/Setup > Detailed Setup > Alerts > Environment Alerts > Supply Pressure > Supply Pressure Lo Alert
Point
Supply Pressure Sensor Alert
TB > Configure/Setup > Detailed Setup > Alerts > Sensor Alerts > Pressure Sensors > Supply Pressure Sensor Alert
Supply Pressure Sensor Alert
Enable
TB > Configure/Setup > Detailed Setup > Alerts > Sensor Alerts > Pressure Sensors > Supply Pressure Sensor Alert
Enable
Supply Sensor Failure
TB > Device Diagnostics > Status > Self Test Status > Supply Sensor Failure
Tag Description
TB > Configure/Setup > Detailed Setup > Instrument > Tag Description
-Continued-
vi
vi