Download 4 - Process Centre Of Excellence.
Transcript
Transducer Block (TB) Menu Structure Parameter Label Menu Structure Processor Alert TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Processor Alert Processor Alert Enable TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Processor Alert Enable Program Memory Alert TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Program Memory Alert Program Memory Alert Enable TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Program Memory Alert Enable Program Memory Manual Recovery TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Program Memory Manual Recovery Program Memory Shutdown TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Program Memory Shutdown Protection TB > Device Variables > Protection Proximity Hi Alert TB > Configure/Setup > Detailed Setup > Alerts > Prox Alerts > Proximity > Proximity Hi Alert Proximity Hi Alert Enable TB > Configure/Setup > Detailed Setup > Alerts > Prox Alerts > Proximity > Proximity Hi Alert Enable Proximity Hi Hi Alert TB > Configure/Setup > Detailed Setup > Alerts > Prox Alerts > Proximity > Proximity Hi Hi Alert Proximity Hi Hi Alert Enable TB > Configure/Setup > Detailed Setup > Alerts > Prox Alerts > Proximity > Proximity Hi Hi Alert Enable Proximity Lo Alert TB > Configure/Setup > Detailed Setup > Alerts > Prox Alerts > Proximity > Proximity Lo Alert Proximity Lo Alert Enable TB > Configure/Setup > Detailed Setup > Alerts > Prox Alerts > Proximity > Proximity Lo Alert Enable Proximity Lo Lo Alert TB > Configure/Setup > Detailed Setup > Alerts > Prox Alerts > Proximity > Proximity Lo Lo Alert Proximity Lo Lo Alert Enable TB > Configure/Setup > Detailed Setup > Alerts > Prox Alerts > Proximity > Proximity Lo Lo Alert Enable Push Down To TB > Configure/Setup > Detailed Setup > Valve and Actuator > Trim > Push Down To Rated Travel TB > Configure/Setup > Detailed Setup > Valve and Actuator > Valve > Rated Travel Relay Type TB > Configure/Setup > Detailed Setup > Instrument > Relay Type Seat Type TB > Configure/Setup > Detailed Setup > Valve and Actuator > Trim > Seat Type Setpoint TB > Device Variables > AO Control-Pre-Char > Setpoint Setpoint Status TB > Device Variables > AO Control-Pre-Char > Setpoint Status Setpoint(D) TB > Device Variables > DO Control > Setpoint(D) Shaft Stem Diameter TB > Configure/Setup > Detailed Setup > Valve and Actuator > Valve > Shaft Stem Diameter Simulate Active TB > Device Diagnostics > Status > Block Error > Block Error.Simulate Active Simulate Jumper ON TB > Device Diagnostics > Status > Self Test Status > Simulate Jumper ON Spring Rate TB > Configure/Setup > Detailed Setup > Valve and Actuator > Actuator > Spring Rate Spring Rate Units TB > Configure/Setup > Detailed Setup > Instrument > Spring Rate Units Static Memory Alert TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Static Memory Alert Static Memory Alert Enable TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Static Memory Alert Enable Static Memory Manual Recovery TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Static Memory Manual Recovery Static Memory Shutdown TB > Configure/Setup > Detailed Setup > Alerts > Elect Alerts > Processor Impaired > Static Memory Shutdown Stroke Time Close TB > Configure/Setup > Detailed Setup > Valve and Actuator > Reference > Stroke Time Close Stroke Time Open TB > Configure/Setup > Detailed Setup > Valve and Actuator > Reference > Stroke Time Open Supply TB > Configure/Setup > Detailed Setup > Alerts > Environment Alerts > Supply Pressure > Supply TB > Device Variables > Pressures > Supply Supply Pressure Hi Alert TB > Configure/Setup > Detailed Setup > Alerts > Environment Alerts > Supply Pressure > Supply Pressure Hi Alert Supply Pressure Hi Alert Enable TB > Configure/Setup > Detailed Setup > Alerts > Environment Alerts > Supply Pressure > Supply Pressure Hi Alert Enable Supply Pressure Hi Alert Point TB > Configure/Setup > Detailed Setup > Alerts > Environment Alerts > Supply Pressure > Supply Pressure Hi Alert Point Supply Pressure Lo Alert TB > Configure/Setup > Detailed Setup > Alerts > Environment Alerts > Supply Pressure > Supply Pressure Lo Alert Supply Pressure Lo Alert Enable TB > Configure/Setup > Detailed Setup > Alerts > Environment Alerts > Supply Pressure > Supply Pressure Lo Alert Enable Supply Pressure Lo Alert Point TB > Configure/Setup > Detailed Setup > Alerts > Environment Alerts > Supply Pressure > Supply Pressure Lo Alert Point Supply Pressure Sensor Alert TB > Configure/Setup > Detailed Setup > Alerts > Sensor Alerts > Pressure Sensors > Supply Pressure Sensor Alert Supply Pressure Sensor Alert Enable TB > Configure/Setup > Detailed Setup > Alerts > Sensor Alerts > Pressure Sensors > Supply Pressure Sensor Alert Enable Supply Sensor Failure TB > Device Diagnostics > Status > Self Test Status > Supply Sensor Failure Tag Description TB > Configure/Setup > Detailed Setup > Instrument > Tag Description -Continued- vi vi