Download 3-Phase PM Synchronous Motor Vector Control Using

Transcript
System Blocks Concept
Index
Primary source
QTimer B0
Secondary source
Position Counter
Cascade mode
Phase B
Quadrature Decoder
Internal digital filter
Phase A
Primary source
QTimer B1
Secondary source
Impulses Counter
Primary source
QTimer B2
Secondary source
System clock / 4
Period Timer
Primary source
QTimer B3
Secondary source
System clock / 4
Time Base
Primary source
QTimer D0
Not used
Secondary source
Figure 4-3 Quad Timer B Configuration
4.3.1.1 Position Sensing
The position and speed sensing algorithm uses all of the timers in module B and an additional timer as a time
base. Timers B0 and B1 are used for position sensing. Timer B0 permits connection of three input signals to
the Quad Timer B1, even if Timer B1 has only two inputs (primary and secondary), accomplished by using
Timer B0 as a Quadrature Decoder only. It is set to count in the quadrature mode, count to zero, and then
reinitialize. This timer setting is used to decode quadrature signals only. Timer B1 is connected to Timer B0 in
cascade mode, in which the information about counting up or down is connected internally to Timer B1,
freeing the secondary input of Timer B1 to be used for the index pulse. Counter B1 is set to count to
+/- ((4*number of pulses per revolution) - 1) and reinitialize after compare. The value of Timer B1 corresponds
to the rotor position.
3-Phase PMSM Motor Vector Control, Rev. 3
Freescale Semiconductor
Preliminary
23