4. Testing Job Aids using the Acterna Test Set
Tools Needed:
• Service description for the circuit under test (e.g. the bandwidth to be verified)
• Acterna FST-2802 TestPad with correct GBICs, quantity 2
• Appropriate fiber optic cables (duplex SC multi-mode or single-mode)
Figure 1. Customer sites with EOS Handoffs
The Ethernet traffic is mapped into SONET sub-rates for efficient transport across the SONET or
DWDM core. This is the enabler of the “Fractional” services alluded to above. Table 1 below
describes the maximum guaranteed Ethernet throughput related to the appropriate SONET
mapping. This mapping flexibility allows for:
• “Right-sizing” the backbone circuit for the customer needs
• Conservation of core bandwidth. (Avoid reserving full STS24c channels for lesser loads)
• Hitless remote upgrades as customer purchases greater bandwidth to meet growing
needs. (no truck roll, no line card swaps as with OC3 to OC12 jump)
Table 1. Relationship between SONET mapping and maximum throughput
Transport Circuit Size
STS1
STS3c
STS6c
STS9c
STS12c
STS24c
STS48c
% GE Interface Speed
5
15
30
45
60
100
100
Bandwidth in Mbps
50
150
300
450
600
1000
1000
© 2004-2005 AT&T Knowledge Ventures All rights reserved..