Download Model 940 PROGRAMMING MANUAL
Transcript
Create a new Configuration File There are times when you are not connected to the drive and would like to develop a new application. This may be accomplished by loading a virtual dive. To create a new configuration file, select “New configuration file” from the Node pull down menu. The following message box should appear. S809 Select the desired drive and click “OK”. This will load a virtual dive onto the Parameter Tree. From here you can set all your parameter setting as well as create your User Program. When done you can use the above “Saving Configuration File to PC” procedure to save your work. Later you can continue to work on your program offline by selecting “Open configuration file” from the Node pull down menu. Motion source (Reference) The 940 can be set up to operate in one of three modes: Torque, Velocity, or Position. The drive must be given a command before it can initiate any motion. The source for commanding this motion is referred to as the “Reference”. With the 940 you have two ways of commanding motion, or two types of References. When the dives command signal is from an external source, for example a PLC or Motion Controller, it is referred to as an External Reference. When the dive is being given its command from the User program or through one of the system variables it is referred to as an Internal Reference. (See table below) “Reference” parameter setting Mode External Internal Torque Analog input AIN1 System variable “IREF” Velocity Analog input AIN1 System variable “IREF” Position MA/MB pulse train inputs + User Program/Interface (Trajectory generator output) User Program/Interface (Trajectory generator) Units All motion statements in the drive work with User units. The statement on the first line of the test program, UNITS=1, sets the relationship between User units and motor revolutions. It simply answers the question: “How many User units are there in one motor shaft revolution?” If this statement is omitted from the program, the motor will operate with encoder counts as User units. Time base Time base is always in seconds i.e. all time-related values are set in USER UNITS/SEC. Enable/Disable/Inhibit drive Set Enable switch function to Run. The 940 drive can be configured to receive its command reference from an external source and not utilize the internal User Program for its motion moves. Essentially acting like a 94 drive. When the “Enable switch function” parameter is set to Run, and the Input 3A is made, the drive will be Enabled. Likewise, toggling input 3A to the off state will Disabled the drive. - 12 Select “Parameter” from the Parameter Tree Window. Select “Enable switch function” from the Parameter View Window. Select “Run” from the popup menu. PM94P01A