Download FSCUT2000 Laser Cutting Control System User Manual
Transcript
16 FSCUT2000 Laser Cutting Control System 2.3 Terminal Instructions 2.3.1 External power source External power source provide direct current 24 V for BCL3762 External IO Board. 24 V and COM of power input terminal are connected to 24 V and 0V of power output interface, respectively. 2.3.2 Servo control interface The three servo control interfaces on BCL3762 are DB15 two-row bores, and pin definition is as below: 8 7 6 5 4 3 2 1 15 14 13 12 11 10 9 The signal definition of matched servo cables is shown as below: 15-pin servo control signal Line Pin Line color Signal Name Pin Line color 1 Yellow PUL+ 9 Yellow-Black 2 3 4 5 6 7 8 Blue Black Orange Red Green Green-Black Brown DIR+ A+ B+ Z+ SON CLR 24V 10 11 12 13 14 15 Blue-Black White-Black Orange-Black Red-Black Purple Brown-Black Signal Name PULDIRABZALM 0V +24V,0V: Supply 24V DC power for servo drive; SON: The output is servo enable signal when servo on; ALM: Alarm, receive servo alarm signal; PUL+, PUL-: Pulse (PULS), differential output signal; DIR+,DIR-: Direction (DIR), differential output signal; A+, A-, B+, B-, Z+, Z-: Three phase of encoder, input signal; The polarity of SON and ALM signal can be modified through hardware jumper. SON ALM ACT_LOW ACT_LOW ACT_HIGH ACT_HIGH When the SON signal jump to ACT_LOW state, low level is active (inputting