Download User Manual - Pid Controller
Transcript
29 List of configuration parameters P-01 General configuration This parameter selects the type of P.I.D. action, enables operator’s access to special functions like manual control of output percentage 0-100%, Autotuning, delayed start, operating as “Simple controller” with fixed setpoint beside standard programming function, possibility to modify cycle data during the cycle, programming of a starting setpoint (to assure the programmed rising gradient in case that kiln temperature at cycle start is too high), number of cycles available to the operator, remote control for cascade applications.. 1st Digit – Type of PID control 0 Single reverse action (Heating) 1 Single direct action (Cooling) 2nd Digit – Access to following functions: Auto-tuning Simple controller Delaied start 0 No No No 1 Yes No No 2 No Yes No 3 Yes Yes No 4 No No Yes 5 Yes No Yes 6 No Yes Yes 7 Yes Yes Yes 3rd Digit – Access to following functions Manual % Starting setpoint Modify data during Output the cycle 0 No No No 1 Yes No No 2 No Yes No 3 Yes Yes No 4 No No Yes 5 Yes No Yes 6 No Yes Yes 7 Yes Yes Yes 77