ADS86xxEVM-PDK Kit Operation www.ti.com When the ALARM feature is enabled, the capture data window shows the indicators for high and low thresholds based on the values programmed. After data capture, if the device detects an ALARM event, EVM diode D1 turns on with a red indicator light. The GUI monitors the status of the ALARM pin on the device. When an ALARM is detected, the ALARM indicator on the GUI starts flashing. The user can read the status of tripped alarms by clicking the Diagnose Alarm? button. The user can also read the ALARM register contents from register map view to detect the state of tripped and active alarms. 7.7 Phase Compensation The ADS86xxEVM GUI includes an analysis page for compensating the phase of signals captured in auto mode. When the signals on different channels are sampled in auto mode, a deterministic phase difference between signals is introduced resulting from the time difference between sampling instants. The phase difference is dependent on sampling rate, input signal frequency, number of channels, and initial phase difference. The phase compensation analysis page compensates for the introduced phase difference and provides the results after phase compensation. For details on phase compensation, see the reference guide Phase Compensated 8-CH Multiplexed Data Acquisition System for Power Automation (TIDU427). The phase compensation analysis page can be activated from the Smart App menu. Figure 28 displays the phase compensation analysis page. SBAU245A – June 2015 – Revised July 2015 Submit Documentation Feedback ADS86xxEVM-PDK Evaluation Module Copyright © 2015, Texas Instruments Incorporated 29