The rear panel comes with 3-slot I/O brackets, two reserved 9-pin D-SUB openings
and a motherboard I/O opening.
3.3 Replacing the Cooling Fans
Figure 3.1 Dual cooling fans
Figure 3.2 Cooling fan maintenance
13
ACP-2000MB User Manual
Operation
There are dual cooling fans as shown in Figure 3.1 located inside the chassis. The
cooling fans are low maintenance and provide adequate cooling to the system. If one
of those cooling fans fails, first please release dual cooling fan holder’s two screws,
move away internal 3.5” HDD storage to find the alarm board. Find FAN1 and FAN2
connectors on alarm board, pull out the power wires of the failed cooling fan from the
alarm board. Replace failed cooling fan with a good one. Please refer to Figure 3.2.