Download AE BUS (HOST) PORT

Transcript
Pinnacle™ 20 kW
Table 4-18. Host Port (AE Bus) Commands (Continued)
Command
179
request
active recipe
step, ramp/
run status,
and ramp/run
time
remaining
180
request
recipe steps
Description
Requests the active recipe step number, the
ramp/run status, and the ramp/run time
remaining.
Number
of
Transmit
Data
Bytes
Number
of
Response
Data
Bytes
0
4
0
1
1
2
The returning packet contains 4 data bytes (32bit value) indicating the following:
• First byte = Active recipe step number
• Second byte = Ramp/run status
• (1 = ramp, 2 = run)
• Third and fourth bytes = Ramp/run time
remaining in seconds. Two decimal places
are implied. For example, a value of 5
would indicate 0.05s or 50 ms.
Note: If the unit has the 100 ms ramp feature,
one decimal is implied (5 = .5 s).
Requests the number of recipe steps that you
have set with command 19; the returning
packet contains 1 data byte (8-bit value)
indicating the number of steps.
Note: Recall that a value of 0 sent with
command 19 disables the ramping
recipe feature.
181
request
recipe step
ramp time
Requests the amount of ramping time you have
set for a specific ramping recipe step (set with
command 21).
Send 1 data byte (8-bit value) indicating the
recipe step.
The returning packet contains 2 data bytes (16bit value) indicating the time in seconds. Two
decimal places are implied. For example, a
value of 5 would indicate 0.05 s.
Note: If the unit has the 100 ms ramp feature,
one decimal is implied (5 = .5 s).
5702266-E
I/O Communication and Control
4-101