Download XBee® Wi-Fi RF Modules

Transcript
XBee® Wi-Fi RF Modules
3 = Digital input,
monitored
4 = Digital output,
default low
5 = Digital output,
default high
AT
Command
Name and Description
D5
DIO5 Configuration. Select/Read function for DIO5
D8
DIO8 Configuration. Select/Read function for DIO8
D9
DIO9 Configuration. Select/Read function for DIO9
LT
PR
PD
DS
AV
M0
Assoc LED Blink Time. Set/Read the Associate LED blink time. If the Associate LED
functionality is enabled (D5 command), this value determines the on and off blink
times for the LED when the module has joined a network. If LT=0, the default blink
rate of 250ms will be used. For all other LT values, LT is measured in 10ms.
Pull-up Resistor. Set/read the bit field that configures the internal resistor status for
the I/O lines. "1" specifies the resistor is enabled. "0" specifies no resistor. The PD
command specifies whether the resistor is pull-up or pull-down. Pin numbers are
listed with the TH module pin first, followed by the SMT module pin (e.g. pin 11/24
indicates pin 11 on the through-hole module and pin 24 on the surface mount
module.)
Bits:
0 – DIO4 (Pin 11/24)
10 – DIO12 (Pin 4/5)
1 – DIO3 / AD3 (Pin 17/30)
11 – DIO10 / PWM0 (Pin 6/7)
2 – DIO2 /AD2 (Pin 18/31)
12 – DIO11/PWM1 (Pin 7/8)
3 – DIO1/AD1 (Pin 19/32)
13 – DIO7 / CTS (Pin 12/25)
4 – DIO0 / AD0 (Pin 20/33)
14 – DIO13/DOUT (pin2/3)
5 – DIO6 / RTS (Pin 16/29)
15 – DIO15 (pin NA/17)
6 – DIO8 / nDTR / Sleep Request (Pin 9/10)
16 – DIO16 (Pin NA/16)
7 – DIN / Config (Pin 3/4)
17 – DIO17 (Pin NA/15)
8 – DIO5 / Associate (Pin 15/28)
18 – DIO18 (Pin NA/14)
9 – DIO9 / On/Sleep (Pin 13/26)
19 – DIO19 (Pin NA/12)
Pull Direction. Set/Read resistor direction for the corresponding bits set in PR (1 =
pull up, 0 = pull down). If the bit is not set in PR, then PD is unused.
Drive Strength Set/Read the output drive strength (output amperes) for DIO lines.
Bits are mapped the same as the PR and PD commands. If the bit is set, the drive
strength is 6mA . Otherwise, it is 2mA.
Analog Voltage Reference. Set/Read the analog voltage reference. This specifies
the volts for an analog reading of 0x03ff, where a reading of 0x200 indicates a
voltage input that is half of VREF. VREF may be one of these two values:
0 – 1.25Volts
1 – 2.5 Volts
PWM0 Duty cycle. Sets the duty cycle of PWM0 for P0=2, where a value of 0x200 is a
50% duty cycle.
© 2013 Digi International, Inc.
Parameter
Range
0 = Disabled
1 = Associated LED
3 = Digital input
4 = Digital output,
default low
5 = Digital output,
default high
0 = Disabled
1 = SleepRq
3 = Digital input,
monitored
4 = Digital output,
default low
5 = Digital output,
default high
0 = Disabled
1 = On/Sleep
indicator
3 = Digital input,
monitored
4 = Digital output,
default low
5 = Digital output,
default high
Default
1
1
1
0, 0x14 - 0xFF (200 2550 ms)
0
0 - 0x7FFF
0x7FFF
0 – 0x7FFF on TH
0 – 0xFFFFF on SMT
0x7FFF on TH
0xFFFFF on SMT
0 – 0x7FFF on TH
0 – 0xFFFFF on SMT
0
0-1
1
0 – 0x03FF
0
103