Download Hitachi Audit Log User Guide

Transcript
[Maintenance] Restore Data
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Maintenance],Restore Data,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+PDEV=HDD000-00
Detailed Information
Item
PDEV
Description
The mounting location of the PDEV
[Maintenance] Set Battery Life
This log information is output when Battery Life Warning SIM is set at the
time of replacing a CM or a battery.
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Maintenance],Set Battery Life,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{Battery,Date,Remained Life}=[{BATTERY-1CA,YYYY/MM/DD,990}],
Num. of Batteries=1
Detailed Information
Item
Description
Battery
The mounting location of the battery
Date
Indicates the date of the setting in "YYYY/MM/DD" format (YYYY:
year, MM: month, DD: day)
Remained Life
The remaining date of the battery shelf life
Num of Batteries
The number of batteries
[Maintenance] Size Change
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Maintenance],Size Change,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+PCB=[CACHE-1CA],Num. of PCBs=1
+SIZE=4096
Detailed Information
Item
4–86
Description
PCB
The mounting location of the PCB (Cache Memory (CM))
Num. of PCBs
The number of PCBs
Audit log examples
Hitachi Virtual Storage Platform Hitachi Audit Log User Guide