Download StrataLink 24 User Manual
Transcript
NOTE: Ensure that only a ‐48 Volt Supply is used and that the wiring is correct. If a +48 VDC supply is used and the Earth ground is wired to the negative terminal shown in the figure, permanent damage to the unit may occur. Figure 18 ‐48 VDC Power Connector using coaxial cable In the figures above, the Power can be connected in two ways, Power‐over‐Ethernet or Direct DC Power as described in the sections below. Running Cable Running the cables depends on the type of installation. In most cases PoE based installation is used, but the power can be directly connected to the unit as a backup or in the case of running long lengths of fiber to the radio unit. PoE Based Installation This section covers installation when powering the unit through Power Over Ethernet (PoE) using a single Cat5e or Cat6 Shielded Twisted Pair (STP) Cable used for management and user traffic. The POE‐GIGE‐48 is shown in the Figure below: Figure 19 POE‐GIGE‐48 Trango Systems, Inc. StrataLink 24 User Manual v 2.2 Doc No. LT‐9045 Rev B 70