Saving the Grid 3.2 Probe – Menu Zero: The TI-MVX is zeroed in much the same way that a mechanical micrometer is zeroed. If the TI-MVX is not zeroed correctly, all of the measurements made using the TI-MVX may be in error by some fixed value. Refer to the section on page 32, for an explanation of this important procedure. Once all the parameters are set, the user has the option of saving or canceling the new grid. 1) Use the UP and DOWN arrow keys to scroll through the new Grid List Items until CREATE NEW GRID? is highlighted. Pulse: The TI-MVX has an adjustable pulse width for both high penetration and resolution applications. The pulse width refers to the duration of time the pulser is on. The options are Spike, Thin, and Wide. Refer to page 58 for a further explanation. Type: Enables the user to select the type of transducer being used from a chart of transducer types. This provides increased linearity between transducers. Refer to page 30 for a further explanation. 2) Press the ENTER key to accept the grid parameters, and activate the confirmation screen. Units: Toggle between English or Metric units. The readout will change from inches to millimeters. 3) Press the OK key to save the New Grid, or the ESC key to cancel the New Grid setup and return to the DATA menu. Velocity: Function to calibrate the TI-MVX by setting the velocity to a known material velocity. Refer to page 33 for further info. 4) Press the MEAS key to return to the measurement screen and begin storing readings. 10.3 One Point: Performs a single point calibration. This option allows the user to automatically calculate the velocity by entering a known sample thickness. Refer to page 33 for further info. Two Point: Performs a two-point calibration. This option allows the user to automatically calculate the velocity by entering a second known sample thickness. Refer to page 34 for further info. Storing a reading Now that a grid has been created, it’s time to make some measurements and store the readings. The following procedures outline this process: Material: Select the material velocity from a chart of basic material types, when a known sample thickness, or material velocity cannot be obtained. Refer to page 79 for further info. Storing a Reading 1) Press the MEAS key once to activate measure menu items. Press the MEAS key multiple times to move right and the ESC key multiple times to move left until the LOC cell is highlighted. 3.3 CAL – Menu Units: Toggle between English or Metric units. The readout will change from inches to millimeters. Velocity: Function to calibrate the TI-MVX by setting the velocity to a known material velocity. Refer to page 33 for further info. One Point: Performs a single point calibration. This option allows the user to automatically calculate the velocity by entering a known sample thickness. Refer to page 33 for further info. -68- -13-