Download x-IMU User Manual 2.0 - x

Transcript
16.1.10
Invalid checksum
Error code:
Description:
16.1.11
Unknown packet header
Error code:
Description:
16.1.12
0x000E
An invalid register value error will be sent if the write register packet contains an invalid
register value for the specific address. This error is only relevant users developing their own
communication software and not using the x-IMU API or x-IMU GUI.
Invalid command
Error code:
Description:
16.1.17
0x000D
A register read-only error will be sent if the write register packet represents an attempt to
write a read-only register. This error is only relevant users developing their own communication software and not using the x-IMU API or x-IMU GUI.
Invalid register value
Error code:
Description:
16.1.16
0x000C
An invalid register address error will be sent if the read or write register packet contains an
invalid register address. This error is only relevant users developing their own communication software and not using the x-IMU API or x-IMU GUI.
Register read-only
Error code:
Description:
16.1.15
0x000B
An invalid number of bytes for packet header error will be sent if the received packet contains
a valid number of bytes, checksum and packet header but the number of bytes does not match
that expected for the specific packet header. This error is only relevant users developing
their own communication software and not using the x-IMU API or x-IMU GUI.
Invalid register address
Error code:
Description:
16.1.14
0x000A
An Unknown packet header error will be sent if the received packet contains a valid number
of bytes and checksum but the header is not recognised. This error is only relevant users
developing their own communication software and not using the x-IMU API or x-IMU GUI.
Invalid number of bytes for packet header
Error code:
Description:
16.1.13
0x0009
An invalid checksum error will be sent if the received packet contains a valid number of
bytes but contains an invalid checksum. This error is only relevant users developing their
own communication software and not using the x-IMU API or x-IMU GUI.
0x000F
An invalid command error will be sent if the command code within the command packet
is not valid. This error is only relevant users developing their own communication software
and not using the x-IMU API or x-IMU GUI.
Gyroscope not stationary
Error code:
Description:
0x0010
A gyroscope not stationary error will be sent if the gyroscope was detected as not being
stationary during the execution of a sample gyroscope bias command (15.1.5 or 15.1.6) and
the execution of the process was aborted. See the gyroscope calibration section (??) for
more information.
35