Download x-IMU User Manual 2.0 - x
Transcript
16.1.10 Invalid checksum Error code: Description: 16.1.11 Unknown packet header Error code: Description: 16.1.12 0x000E An invalid register value error will be sent if the write register packet contains an invalid register value for the specific address. This error is only relevant users developing their own communication software and not using the x-IMU API or x-IMU GUI. Invalid command Error code: Description: 16.1.17 0x000D A register read-only error will be sent if the write register packet represents an attempt to write a read-only register. This error is only relevant users developing their own communication software and not using the x-IMU API or x-IMU GUI. Invalid register value Error code: Description: 16.1.16 0x000C An invalid register address error will be sent if the read or write register packet contains an invalid register address. This error is only relevant users developing their own communication software and not using the x-IMU API or x-IMU GUI. Register read-only Error code: Description: 16.1.15 0x000B An invalid number of bytes for packet header error will be sent if the received packet contains a valid number of bytes, checksum and packet header but the number of bytes does not match that expected for the specific packet header. This error is only relevant users developing their own communication software and not using the x-IMU API or x-IMU GUI. Invalid register address Error code: Description: 16.1.14 0x000A An Unknown packet header error will be sent if the received packet contains a valid number of bytes and checksum but the header is not recognised. This error is only relevant users developing their own communication software and not using the x-IMU API or x-IMU GUI. Invalid number of bytes for packet header Error code: Description: 16.1.13 0x0009 An invalid checksum error will be sent if the received packet contains a valid number of bytes but contains an invalid checksum. This error is only relevant users developing their own communication software and not using the x-IMU API or x-IMU GUI. 0x000F An invalid command error will be sent if the command code within the command packet is not valid. This error is only relevant users developing their own communication software and not using the x-IMU API or x-IMU GUI. Gyroscope not stationary Error code: Description: 0x0010 A gyroscope not stationary error will be sent if the gyroscope was detected as not being stationary during the execution of a sample gyroscope bias command (15.1.5 or 15.1.6) and the execution of the process was aborted. See the gyroscope calibration section (??) for more information. 35