Download User Manual - UniSoft Geotechnical Solutions Ltd

Transcript
Depth Bidirectional Cell
Use this entry to specify the depth of the Bidirectional Cell.
Shaft Buoyant Weight
In order to move the pile above the cell level upward, the bidirectional cell must overcome the pile weight in addition
to the soil resistance. Moreover, an actual test includes the effect of the pore pressure acting at the cell level after
the bond in the pile is broken (the first effect of engaging the cell), which pore pressure then introduces a water
force that acts both upward and downward. Upward, the water force reduces the effect of the pile weight to that of
the buoyant value. Downward, the water force adds to the cell load in engaging the downward response of the pile.
(So does the pile weight, but as this is the same for a head-down test, this effect is conventionally disregarded).
The User decides whether to "include" or "disregard" the effect of the pore pressures on the pile ("Shaft Buoyant
Weight") for the bidirectional test simulation. When "included", UniPile uses the pore pressure at the cell level to
calculate the buoyant weight of the shaft portion located above the cell level and add this to the calculated shaft
resistance to generate the simulated upward load-movement curve. Similarly, the water force is added to the cell
load in engaging the downward response (the shaft and toe resistances below the cell level).
When "disregarded", UniPile makes no adjustment for the water force for either upward or downward simulation of
the load movement curves of the bidirectional test.
Because, the cell load is determined from the pressure at the pump placed at the ground surface, the cell pressure
is actually larger than that measured in the pump (the hydraulic fluid is water). The difference corresponds to the
head of water between the cell and the pump. Moreover, the pore pressure in the soil at the cell level can only act
on the area not covered by the cell(s). Therefore, on the approximation that the head of water between the cell and
the pump is equal to the head of water corresponding to the pore pressure at the cell level, the water force at the
cell level corresponds to the pore pressure times the full pile cross section.
8.5 Analysis Options
This section of the settings allows the user to disable portions of the analysis to speed up the calculations and to
reduce the output produced by the software.
Depending on the type of version installed in your computer, some of these features may not be available.
Page 42 of 67