Download Operation manual HERKULES PFP
Transcript
Operation 5.2.2 Hints to achieve good coating results ➤➤ Hold the spray gun at right angles (90°) to the area to be coated. If the spray gun is held under a different angle, the coating becomes irregular and blotchy (see Fig. 18). ➤➤ Ensure an even speed and move the spray gun parallel to the area to be coated. Waving the spray gun causes irregular coating (see Fig. 19). ➤➤ Move the spray gun with your arm and not with your wrist. ➤➤ Already move the spray gun before pulling the trigger. In this way, you will achieve perfect, soft and smooth overlapping of the spray jet and avoid excessively thick application of material at the beginning of the spraying process. ➤➤ Release the trigger before stopping the movement. ➤➤ Replace the spray nozzles before these are worn. right ng wro Fig. 18: Spray angle thin layer thick thin layer layer Area to be coated wrong Fig. 19: Do not wave! Worn nozzles cause higher material consumption and have a negative effect on the quality of coating. 5.2.3 Changing material drum Exchange the material drum when it is empty. After processing of 6 material drums, the pump must be flushed intermediately in order to remove material deposits from the unit and prevent a blockage of the pump (see chapter 5.2.4). 1. Regulate the air inlet pressure of the pump completely back. 2. Set the ram control lever to “Stop”. 3. Open the compressed air shut-off valve for the container ventilation. 4. Set the ram control lever to position “Up”, to move the ram up. 5. Once the sealing lip of the follow plate reaches the top of the material drum, close the compressed air shut-off valve for the container ventilation. 6. Once there is sufficient space for removing the material drum, set the ram control lever to position “Stop”. 7. Remove the old material drum. 8. Place the new material drum centered below the follow plate. 9. Open the ventilation ball valve at the follow plate. 10.Set the ram control lever to position “Down” to move the ram down. 11.Once all air has escaped from the material container, close the ventilation ball valve on the follow plate. 12.Adjust the optimal spraying pressure using the air pressure regulator for the pump. 28 Translation of the original operation manual HERKULES PFP HERKULES PFP_BAoDB_en_1402_B · rs