Rod clevis
Latch cylinder
6: Assembly
Door cylinder
Latch Cylinder Adjustment.
Procedure
1. After Door cylinder adjustment is found to be OK, the latch cylinder must be adjusted
according the following procedure.
2. Power the elevator to close and latch
3. Check whether the closed latch is in contact with it’s hard stop on the left-hand door. Stop
is located on the inside (back) of the bottom latch strap. You may need to use markingpaint (Blue-Dye) to get a proper indication, as this hard stop is difficult to reach with a
feeler gauge. When latch does not contact hard-stop IN, turn rod-end clevis OUT.
(lengthen Cylinder)
4. In the condition described in item 2, the elevator closed signal on port ‘XP’ MUST be
present. (1,000 Psi / 6,895 KPa) When NO “elevator-closed-signal” (1,000 Psi / 6,895 KPa
on “XP”) Is present, turn rod-end clevis IN.(Shorten Cylinder)
5. Open the elevator and check whether latch is in contact with its Hard-stop for the open
position. If not turn the rod-end clevis IN. (Shorten Cylinder)
6. REPEAT these steps until OK.