4 Safety Function Blocks
DiagCode (hexadecimal)
8012
Status name
Muting Active
Status description and output results
A muting sequence is in operation for one of the following.
• A change to TRUE was detected in the second muting switch of
S_MutingSwitch11 and S_MutingSwitch12.
• Both S_MutingSwitch11 and S_MutingSwitch12 were started in
the same cycle.
Monitoring for DiscTimeEntry was stopped. Monitoring for MaxMutingTime was started.
Ready = TRUE
S_AOPD_Out = TRUE
S_MutingActive = TRUE
Error = FALSE
4
SF_MutingPar_2Sensor
NX-series Safety Control Unit Instructions Reference Manual (Z931)
4 - 89