4 Safety Function Blocks DiagCode (hexadecimal) 8012 Status name Muting Active Status description and output results A muting sequence is in operation for one of the following. • A change to TRUE was detected in the second muting switch of S_MutingSwitch11 and S_MutingSwitch12. • Both S_MutingSwitch11 and S_MutingSwitch12 were started in the same cycle. Monitoring for DiscTimeEntry was stopped. Monitoring for MaxMutingTime was started. Ready = TRUE S_AOPD_Out = TRUE S_MutingActive = TRUE Error = FALSE 4 SF_MutingPar_2Sensor NX-series Safety Control Unit Instructions Reference Manual (Z931) 4 - 89