The data objects and variations supported by the SCADAPack series controllers are found in the DNP Device Profile Document - Slave and DNP Device Profile Document - Master sections of this user manual. In general there are two categories of data within each data type, static objects and event objects. Static objects contain the current value of the field point or software point. Event objects are generated as a result of the data changing. In addition to the object group and variation data objects can be assigned to classes. In DNP there are four object classes, Class 0, Class 1, Class 2 and Class 3. Class 0 contains all static data. Classes 1, 2 and 3 provide a method to assign priority to event objects. While there is no fixed rule for assigning classes to data objects typically class 1 is assigned to the highest priority data and class 3 is assigned to the lowest priority data. This object library structure enables the efficient transfer of data between master stations and outstations. The master station can poll for high priority data (class 1) more often than it polls for low priority data (class 3). As the data objects assigned to classes is event data when the master polls for a class only the changed, or event data, is returned by the outstation. For data in an outstation that is not assigned a class the master uses a class 0 poll to retrieve all static data from the outstation. DNP allows outstations to report data to one or more master stations using unsolicited responses (report by exception) for event data objects. The outstation reports data based on the assigned class of the data. For example the outstation can be configured to only report high priority class 1 data. 2.1.1.1 Internal Indication (IIN) Flags An important data object is the Internal Indications (IIN) object. The Internal Indication (IIN) flags are set by a slave station to indicate internal states and diagnostic results. The following tables show the IIN flags supported by SCADAPack controllers. All bits except Device Restarted and Time Synchronization required are cleared when the slave station receives any poll or read data command. The IIN is set as a 16 bit word divided into two octets of 8 bits. The order of the two octets is: First Octet Second Octet 2.1.1.1.1 7 IIN First Octet 6 5 4 3 2 1 0 Bit Number First Octet Bit Description 0 1 2 3 4 5 6 last received message was a broadcast message Class 1 data available Class 2 data available Class 3 data available Time Synchronization required not used (returns 0) Device trouble • Indicates memory allocation error in the slave, or • For master in mimic mode indicates communication failure with the DNP3 User and Reference Manual June 18, 2007 7