V. VME Interface
A. Setting the VME Board Base Address
Using a VME 64x crate, the board base address is set according to the slot
geographical address map. The VME address switch SW2 should be disabled (all
switch in position off) to assure a correct address decoding. Any 5 consecutive
address lines range can be used (A31..A27; A27..A22 etc…) for the board address
mapping, giving a maximal address space of 128 MByte per VME slot if using the 5
upper address lines (A31.. A27). The decoded address lines are selected by the
rotating hex coder switch SW3.
SW3
0
1
2
3
4
5
6
7..F
Address lines decoded
A31…A27
A30…A26
A29…A25
A28…A24
A27…A23
A26…A22
A25…A21
Not available
Address space
128 MByte
64 MByte
32 MByte
16 MByte
8 MByte
4 MByte
2 MByte
B. Board base address adjustment
On normal VME64x crates the adjustment can only be set by choice of the correct
slot and by use of the switch SW3. On crates where geographical addressing is not
available, the geographical addresses should be set manually, using switch SW2.
SLOT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
GA_Lines
00001
00010
00011
00100
00101
00110
00111
01000
01001
01010
01011
01100
01101
01110
01111
10000
10001
0
08000000
10000000
18000000
20000000
28000000
30000000
38000000
40000000
48000000
50000000
58000000
60000000
68000000
70000000
78000000
80000000
88000000
Paul Scherrer Institut • 5232 Villigen PSI
1
04000000
08000000
0c000000
10000000
14000000
18000000
1c000000
20000000
24000000
28000000
2c000000
30000000
34000000
38000000
3c000000
40000000
44000000
2
02000000
04000000
06000000
08000000
0a000000
0c000000
0e000000
10000000
12000000
14000000
16000000
18000000
1a000000
1c000000
1e000000
20000000
22000000
3
01000000
02000000
03000000
04000000
05000000
06000000
07000000
08000000
09000000
0a000000
0b000000
0c000000
0d000000
0e000000
0f000000
10000000
11000000
4
00800000
01000000
01800000
02000000
02800000
03000000
03800000
04000000
04800000
05000000
05800000
06000000
06800000
07000000
07800000
08000000
08800000
5
00400000
00800000
00c00000
01000000
01400000
01800000
01c00000
02000000
02400000
02800000
02c00000
03000000
03400000
03800000
03c00000
04000000
04400000
6
00200000
00400000
00600000
00800000
00a00000
00c00000
00e00000
01000000
01200000
01400000
01600000
01800000
01a00000
01c00000
01e00000
02000000
02200000