TEX1002LCD
5.4.2 Power Menu (Pwr)
This screen holds all readings related to equipment output power::
Menu 5
Fwd
Rfl
Forward power reading.
Reflected power reading.
Note that these are readings, rather than settings, and cannot be edited (note
the empty triangle). To change power setting, go to the default menu as outlined
earlier..
5.4.3 Power Amplifier (P.A) Menu
This screen is made up of four lines that can be scrolled using the
buttons and shows the readings relating to final power stage:
and
Menu 6
Note that these are readings, rather than settings, and cannot be edited (note the
empty arrow).
VPA
Voltage supplied by amplifier module.
Eff
Efficiency based on ratio of forward power to amplifier module power,
in percent ( FWD PWR/(Vpa x Ipa) % ).
Tmp
Equipment internal temperature reading.
IPA
18 / 26
Current draw of amplifier module.
Rev. 1.0 - 22/08/14