Download MULTICAL® 302 - Technical Description
Transcript
MULTICAL® 302 7.6.2 Average temperatures MULTICAL 302 currently calculates the average temperatures of inlet and outlet (T1 and T2) in C without decimals. The background calculations E8 and E9 (m3 x T1 and m3 x T2) are carried out with every volume increase (every 0.01 m3 or 0.001 m3 determined by the meter's configuration). The display is updated every day at midnight. The average temperatures are thus volume weighted and can be used directly for checking purposes. Average Yearly data Year-to-date average (since latest target date MM.DD) Month-to-date average (since latest target date DD) Type of registration: Monthly data Year-to-date average of T1. (Current date with a stipulated line under year or month is displayed immediately BEFORE this reading) 42 Kamstrup A/S ∙ Technical Description ∙ 5512‐1334_E1_GB_05.2015