Download Operator Station

Transcript
PAGE 48
MAN0023-10
6 APR 2002
CH. 4: EMBEDDED DATA
4.17.3 Data Indirectly Specified.
This option allows the programmer to indirectly specify the register which contains the data for the trend,
i.e. the contents of the register, which is specified in the Location section of the Remote Data Source,
specifies the register that contains the data for the trend.
4.17.4 Control Data from Remote Device
This option allows the programmer to control the set-up of the trend from registers stored in the
automation equipment. The structure for setting up the trend is described further in this paragraph.
The data structure is as follows:
Offset +0
Time Base
Time Base
Offset +1
Ch. 1 Scale
Offset +2
Ch. 1 Data
Offset +3
Ch. 2 Scale
Offset +4
Ch. 2 Data
Offset +5
Width
0 = maximum update rate;
1 = 1/10s per plot
X = X/10s per plot, up to X=10
Scale Maximum value of Y-axis for that channel; if 0 channel is not plotted.
Data
Raw register values. Negative values are plotted at full scale.
Width Number of samples across the display
100 = 1 pixel per plot
50 = 2 pixels per plot
25 = 4 pixels per plot
10 = 10 pixels per plot
Any other value, the nearest to the above 4 is used.
If the Control Data from Remote Device option is not clicked then the trend is set-up as follows.
The Time Base is set by the Trend Width.
The scale is set by the Minimum and Maximum Range
The data for the first trace is taken from the register specified or indirectly specified in the Location field
The data for the second trace is taken from the following register specified or indirectly specified in the
Location field.
Note: When Control Data from Remote Device is selected, the data to set-up the structure of the trend is
only read once, when you first go onto a screen where the trend is embedded. The data for the trend is
read continuously.
4.17.5 To Embed a Trend
1. Select Embedded Data from the Edit menu
2. Select Trend under Type.
3. Select a Data Type (register or other) and a Location.
4. To display axes with the graph, click the Enable Axes under Format.
5. Click OK.
Note: The trend uses up 3/4 of a menu or submenu page and as such overwrites whatever data is on that
page.