Download English 220.87 KB
Transcript
User manual WAP Extension V1.4.32b 0xF70E Status 0xF712 Setpos Mot A 0xF714 Setpos Mot B 0xF716 Setpos Mot C 0xF718 Setpos Mot D 0xF71A 0xF71C 0xF71E 0xF720 0xE040 0xE100 0xE1C0 0xE280 0xE030 0xE0F0 0xE1B0 0xE270 0xE032 0xE0F2 0xE1B2 0xE272 0xE046 0xE106 0xE1C6 0xE286 0xF722 TrigPos Mot A TrigPos Mot B TrigPos Mot C TrigPos Mot D APOS Mot A APOS Mot B APOS Mot C APOS Mot D Max Speed Mot A Max Speed Mot B Max Speed Mot C Max Speed Mot D Max Acceleration A Max Acceleration B Max Acceleration C Max Acceleration D Max Current Mot A Max Current Mot B Max Current Mot C Max Current Mot D Spec. Max Current Mot A Spec. Max Current Mot B Spec. Max Current Mot C Spec. Max Current Mot D Spec. Max Current Mot A E-Stop Spec. Max Current Mot B E-Stop Spec. Max Current Mot C E-Stop Spec. Max Current Mot D E-Stop Error Mot A Buffered Error Mot A 0xF724 0xF726 0xF728 0xF72A 0xF72C 0xF72E 0xF730 0xE050 0xE05E LinMot ® Bit 11: reserved Bit 12: Init Request Flag Motor A (Run State only)1 Bit 13: Init Request Flag Motor B (Run State only) Bit 14: Init Request Flag Motor C (Run State only) Bit 15: Init Request Flag Motor D (Run State only) Status Wort: Bit 0: Init done Bit 1: Controller is in state RUN Bit 2: Controller is in state ERROR Bit 3: Controller is in state INIT Bit 4: Controller is in state DISABLE Bit 5: Controller is in ESTOP Bit 6: Error Pending Flag Bit 7: Warning Pending Flag Bit 8: Trigger Level A Bit 9: Trigger Level B Bit 10: Trigger Level C Bit 11: Trigger Level D Bit 12: In Position Flag of Motor A Bit 13: In Position Flag of Motor B Bit 14: In Position Flag of Motor C Bit 15: In Position Flag of Motor D Direct Set Position for Motor A without handshake (0x7FFFh = Feature disabled) Direct Set Position for Motor B without handshake (0x7FFFh = Feature disabled) Direct Set Position for Motor C without handshake (0x7FFFh = Feature disabled) Direct Set Position for Motor D without handshake (0x7FFFh = Feature disabled) Stored position of Motor A at any rising 0 1 edge of the Trigger Input A Stored position of Motor B at any rising 0 1 edge of the Trigger Input B Stored position of Motor C at any rising 0 1 edge of the Trigger Input C Stored position of Motor D at any rising 0 1 edge of the Trigger Input D Actual position of Motor A Actual position of Motor B Actual position of Motor C Actual position of Motor D Max. Speed of Motor A Max. Speed of Motor B Max. Speed of Motor C Max. Speed of Motor D Max. Acceleration of Motor A Max. Acceleration of Motor B Max. Acceleration of Motor C Max. Acceleration of Motor D Max. Current of Motor A Max. Current of Motor B Max. Current of Motor C Max. Current of Motor D Max. Current of Motor A (in the Run State with activated Feature “Spec Current on E-Stop” Max. Current of Motor B (in the Run State with activated Feature “Spec Current on E-Stop” Max. Current of Motor C (in the Run State with activated Feature “Spec Current on E-Stop” Max. Current of Motor D(in the Run State with activated Feature “Spec Current on E-Stop” Max. Current of Motor A (On E-Stop with activated Feature “Spec Current on E-Stop” Max. Current of Motor B (On E-Stop with activated Feature “Spec Current on E-Stop” Max. Current of Motor C (On E-Stop with activated Feature “Spec Current on E-Stop” Max. Current of Motor D (On E-Stop with activated Feature “Spec Current on E-Stop” Error state of Motor A Buffered Error state of Motor A 1 The single Init flags for each motor can only be used within the RUN state. With each rising edge the configured homing routine will be executed. The speed and acceleration can be controlled with the parameters Max. Speed and Max. Acceleration as it is done with a normal positioning commands. NTI AG / LinMot 08.09.2003 2/7