Download User Manual - Limcon V3 Connection Design

Transcript
Checks that are not relevant for the compound connection are omitted.
These are:
• The check on the weld to the supporting member.
• The yield check on the section adjacent to the weld.
• HSS supporting member checks.
KTG DIALOG BOX
COMPONENT BRACE DIALOG BOX
Effective Lengths
While buckling in single brace connections is checked using an effective
length factor (k) of 1.0 or 1.2, the value used for a beam/column brace is
typically half of that. This recognizes the restraint provided by adjacent
members and transverse tension in the gusset plate.
70 • 4:Technical Notes