Download USER MANUAL VECTIS-MAX Version 1.1
Transcript
19. TUTORIALS 19.2.4 19.2. STEADY STATE PORT FLOW Selecting Boundaries The boundaries can be selected either automatically or manually. For a geometry as simple as this it is recommended that the boundaries be defined manually. To do this use a combination of the ’Chop’ and ’Mark Face’ commands. Figure 19.22: Using the chop geometry command The boundaries can be selected either manually or automatically. To manually select the boundaries, first open the Boundary Painting Tab in the Operations menu. Then select with the left mouse button the colour required by clicking on the number of the boundary required. Once a colour has been selected, the row that contains that colour will turn yellow. Then either the MARK LINE or a combination of the CHOP and MARK FACE commands can be used to select the different boundaries. The automatic method works on separating surfaces that are at angles greater to each other than is specified in the Auto Paint Angle option, the default being 45 degrees. Having specified an angle, selecting the Auto Paint button divides the various surfaces on the model into separate colours. The Reduce command can then be used to consolidate on the number of colours used and organise these so that the minimum number of colours are used, whilst still separating surfaces. Once the surfaces have been separated, the user may need to reorganise the sequence and/or contents of each colour so that items such as inlet/outlet boundaries are uniquely defined. For this example, the boundaries should be painted as described in Table 19.1. It is possible to drag and drop triangles from one boundary to another by clicking and dragging on the number of triangles in that boundary. For this example, there are four boundaries - the inlet, defined as the back of the plenum chamber (i.e. opposite the inlet port); the outlet, defined as the bottom of the cylinder; the valve, used for boundary refinement; and the rest, which are walls. ©Ricardo Software, December 2009 388
Related documents
VibWire-108 Manual - Keynes Controls Ltd
650SE Supplement
meterbuilder™ mb-1 programmable meter for analog sensors
VECTIS 2015.2 Release Notes
VECTIS 2012.1 Release Notes
Experiment No. 9. Absorption of alpha particles and electrons
Universidade Federal do Rio de Janeiro Escola Politécnica
VFS-Wind® User Manual
VibWire-101 - Keynes Controls Ltd
Blodgett Combi Specifications
USER INSTRUCTIONS for the Fire Service Helmet
esplosioni di polveri organiche naturali - Unitus DSpace