ABC
User Manual
4.1. Cage Factor – Coarse Tuning
When controlling the calibrator cage position the actual cage position feedback has a long
delay. For this reason the system uses a pulse technique to operate the cage motor
according to a fixed ratio between the cage position error and the motor operation time.
This ratio is called Cage Factor and it can be found using the Cage Factor screen.
In the IBC screen press the Cage Factor button and follow this procedure to find the cage
factor:
1. Place a target in front of the gap sensors 7 and 8. The best method is to assemble the
IBC pipe on the die.
2. Press and hold Close Cage to close the calibrator cage until both sensors 7 and 8
show readings.
3. Press and hold Close Cage for about 7 second and release. The system will show a
value at Calculated Factor.
4. Press and hold Open Cage for about 7 seconds. The system will update the
Calculated Factor.
5. Repeat opening and closing the cage several times and check the Calculated Value. It
is recommended to test the factor at longer and shorter movements of the cage and at
different positions of the cage.
The Calculated Factor will later be used as the Cage Factor.
Figure ‎4.1-1 – Cage Factor Tuning
www.sysmetric-ltd.com
- 33 -