Download User`s manual complete - Sea
Transcript
SECTION 3 USING THE KEYPAD/DISPLAY ________________________________________________________ 3.5.4 ZERO MACHINE (SET RESOLVER OFFSET) This selection is used to auto zero the resolver. To set the machine zero (resolver offset) perform the following: 1) Select “3: SET MACHINE TIMING” and observe the “POS:” field. Verify that as the machine is rotated forward (either jogged or barred) that the position increases linearly from 0 through 359. If not, swap the S1 and S3 leads of the resolver at the HSMCCSD2 resolver connector. Then verify that the position then indeed does increase with forward movement. Press <ESC> to exit back to the primary set-up menu. 2) Position the machine at machine zero (spindle centered on No Can/No Print Sensors). 3) Auto zero the resolver by selecting “4: ZERO MACHINE” from the primary set-up menu. Enter “0” to zero the resolver. The timing set-up menu will be displayed, now showing the “POS:” at zero. 4) The HSM-CCSD2 will calculate the actual offset value required to make this the 000 position and will display this number in the offset field. 5) Exit back to the primary set-up menu by pressing <ESC>. Exit back to the default screen by pressing <ESC> again. ________________________________________________________ 3.6 “QC BLOW-OFF” KEY This key is used to blow-off a can from a selected spindle at the Pin Chain QC Blow-off port. To blow-off a can, press the “QC BLOWOFF” key. The display will then prompt “Enter Spindle to Blow Can off”. Enter the desired spindle number (1-24) and press enter. A can from that spindle will be blown off at the Pin Chain QC blow-off port. HSM-CCSD2 User’s Manual SYSTEMS Electronics Group - 37 -