PROBLEM SOLVING - 2
PROBLEM
CAUSE
The vacuum bag has not ·
been sealed correctly.
·
·
·
·
·
The gas percentage in
the vacuum bag is
insufficient (optional).
·
·
·
·
SOLUTION
The vacuum bag was not placed ·
over the seal bar correctly.
Place the vacuum bag tightly and
smoothly over the seal bar. Ensure
that the opening of the bag always
stays inside the vacuum chamber.
·
·
Set the seal time longer or shorter.
Replace the silicon rubber.
·
Replace the Teflon tape.
·
Clean the opening of the vacuum
bag.
Check this by switching the gas
function off.
The seal time has been set too
long or too short.
The silicon rubber in the contra
bar is damaged and/or worn.
The Teflon tape has been
damaged.
The opening of the vacuum bag
has been contaminated.
There has been gas flushed too
far back
·
The gas bottle is empty or nearly ·
empty.
·
The gas bottle is still closed.
Replace the gas bottle.
The gas flushing value has been ·
set too long or too short.
·
The gas pressure has been set
incorrectly.
Increase or decrease the gas flush
value.
Check the pressure gauge to
ensure that the gas pressure has
been set to 1 atmosphere
(1ATO-).
Ascertain whether the gas bottle
valve is closed. If so, open it.
WARNING! The pressure of the gas
mixture may never be higher than 1
atmosphere.
WARNING
è
To prevent fire and/or other irreparable damage, the values and types of the
Replacement fuses must correspond with the originals.