Download USER MANUAL FOR TABLE MODELS SPECIALS
Transcript
PROBLEM SOLVING - 2 PROBLEM CAUSE The vacuum bag has not · been sealed correctly. · · · · · The gas percentage in the vacuum bag is insufficient (optional). · · · · SOLUTION The vacuum bag was not placed · over the seal bar correctly. Place the vacuum bag tightly and smoothly over the seal bar. Ensure that the opening of the bag always stays inside the vacuum chamber. · · Set the seal time longer or shorter. Replace the silicon rubber. · Replace the Teflon tape. · Clean the opening of the vacuum bag. Check this by switching the gas function off. The seal time has been set too long or too short. The silicon rubber in the contra bar is damaged and/or worn. The Teflon tape has been damaged. The opening of the vacuum bag has been contaminated. There has been gas flushed too far back · The gas bottle is empty or nearly · empty. · The gas bottle is still closed. Replace the gas bottle. The gas flushing value has been · set too long or too short. · The gas pressure has been set incorrectly. Increase or decrease the gas flush value. Check the pressure gauge to ensure that the gas pressure has been set to 1 atmosphere (1ATO-). Ascertain whether the gas bottle valve is closed. If so, open it. WARNING! The pressure of the gas mixture may never be higher than 1 atmosphere. WARNING è To prevent fire and/or other irreparable damage, the values and types of the Replacement fuses must correspond with the originals. HENKELMAN users manual 31