Download User`s Manual

Transcript
Multiprocessor Support (Remote Start)
This command sets a Busy/Failed Selftest bit and starts
selftest. When the selftests are complete, it clears the bit that
started the test. If the selftests pass, the Busy/Failed Selftest
bit is cleared. If not, the address of an error message buffer
is written to two GCSR registers, GCSR1 and GCSR2.
0x0002 Setup VMEbus Slave Decoder 1
This command sets Slave Decoder 1 starting, ending,
translation, and select addresses, as well as write post and
snoop control, using values found in the GCSR registers.
0x0004 Read (a PowerBase local resource)
This command reads data from an address found in two
GCSR registers, and copies it into two other GCSR registers.
0x0008 Write (a PowerBase local resource)
This command copies data from two GCSR registers and
writes it into the address found in two other GCSR registers.
0x0010 Request Board Information or query for residual data
This command returns the address of the board residual
data. It will locate the start of free memory and initialize a
residual data structure.
Using the GO Command through GCSR
A remote processor can initiate program execution in a local
MVME130x PowerBase boardÕs dual-port RAM by issuing a remote
GO command using the Global Control and Status Registers
(GCSR). The remote GO command causes the following sequence:
❏
❏
❏
Remote processor places the PowerBase execution address in
general purpose registers 0 and 1 (GPCSR0 and GPCSR1)
Remote processor sets bit 8 (SIG0) of the VMEchip2 LM/SIG
register.
PowerBase installs breakpoints and begins execution.
The result is identical to the MPCR method (with status code B)
described in a previous section.
5-15
5