Q9: Why can not the configuration program search for the target
module?
A: The serial setting of configuration program is not consistent with the serial setting of the
module;
The module is in auto-work mode, please reset it , be sure LED1 and LED2 is illumed,
and then retry the search.
Q10: To modify the parameters with configuration program, why
does it show the error ’used prohibitive operating symbol’?
A: Please disconnect the network connection first, and then refer the modified parameters.
Q11: Why cannot web pages of the WEB server open?
A: The reasons maybe include,
Whether the WEB server is forbidden
Whether the server port is set correctly or not, if the port is set to the number except 80,
then it’s needed to input the port number in the address bar while using a browser, such as
http://192.168.1.100:2000.
Q12: When user sets the serial to the baud rate it does not support,
the module can’t be connected to, then how to correct it ?
A: Resume it to the manufacturer setting, the approaches is as follow,
1. Open the serial debugging software, such as serial master, set the serial parameters
to 115200bps/8 bits of data bits/1 bit of stop bits/no parity of parity bit/no flow control.
2. Input ‘at+’(no contain quotation marks and contain enter) in the sending column of
the software, choose periodic sending, the period is set to 50ms.
3. Reset the module, if it return ‘+OK’, then stop the periodic sending.
4. Send the command ’AT+QVER’ to look over the return message, if the message
includes B1.xx field, then it joins in bootloader mode successfully, otherwise it’s not
in, retry from the 2th approach.
123 | P a g e