Download 3 shape - Wieland Dental
Transcript
5.4.3 Validation The Validation function tests the restoration model against the values preset in Dental System Control Panel Material Settings section or defined manually in the Validation dialog, and marks the areas needing attention with red exclamation marks, whereas successfully validated parameters are marked with green ticks. Click on the exclamation mark to get a description of a problem. button in the In order to run the validation process, click Validation Visualization toolbar of DentalDesigner to compare the model values with the predefined ones. The Validation dialog box appears in the right upper corner of the modelling window (see image to the left). The Validation parameters (Thickness, Area, Strength) can be set to match your particular case. Click Update to update each time the parameters are changed unless Update Automatically check-box is selected. Select Apply Material Settings check-box to apply the material settings from Dental System Control Panel. Dental System Control Panel 3Shape Dental System Control Panel is an application that enables you to customize the necessary settings to get a fully satisfying performance from the 3Shape Dental System applications. either from DentalManager or from the Dental System Control Panel is started by double-clicking the corresponding icon desktop. The image below illustrates the main window of Dental System Control Panel and its categories: 1. Main toolbar 2. Main window