Chapter 8 Options 57 8.4 Complete Set Of Cables 8.4.1 Parallel Signal Cables The parallel signal cable is compulsory in the parallel system, and its description is given in Table 8-5. Refer to 3.4.2 Connecting Parallel Signal Cables for the connection of the parallel signal cables. Table 8-5 Parallel signal cable description Model UH62SA1SL3 Name Description Parallel signal cable For N + 1 parallel system, N + 1 pieces of parallel signal cables are required to be configured. For example, 2 pcs of parallel signal cables for 1 + 1 parallel system, 3 pcs of parallel signal cables for 2 + 1 parallel system, 4 pcs of parallel signal cables for 3 + 1 parallel system Appearance 8.4.2 Battery Cables The battery cable is an option when the long back-up UPS is selected. When you select standard UPS, the battery cable is the accessory in standard configuration, see Table 8-6 for its description. Refer to 2.5.2 Connecting Battery Cables for the detailed operation. Table 8-6 Battery cable description Model UHA2SA1SL4 Name Description Battery cable When standard UPS is selected, the battery cable is configured in the UPS accessories, and there is no need to select it again; When the long back-up UPS is selected, and the UPS is required to configure with a standard battery module U16-07C1, the battery cable needs to be selected Appearance 8.5 Guide Rail For Rack Installation The guide rail for rack installation is used in the rack installation of UPS, POD (optional) and battery module (optional). See Table 8-7 for its description. Refer to 2.4.2 Rack Installation for the rack installation procedures. Table 8-7 Guide rail for rack installation Model UF-RMKIT2438 Name Description Guide rail for rack installation A set of guide rail includes a left guide rail and a right guide rail,and its bearing is 50kg. The guide rail is used for the selected rack installation. It is applicable to various server cabinets, UPSs, modularized batteries and PODs with standard dimension Appearance 8.6 Communication Options And Monitoring Options The communication options and the monitoring options are listed in Table 8-8. Table 8-8 Communication options and monitoring options Name SIC card (can be connected to the net port type of temperature/humidity sensor) Model Description UF-SNMP810 Conduct web remote monitoring for the UPS through TCP/IP protocol and Internet; Support remote safety shutdown function; Provide an extended net port, cascade at most 8 temperature/humidity sensors Liebert® ITA 10kVA UPS User Manual Appearance