Download User manual for - Hyundaipower.ca
Transcript
EN 1. Press the ECON switch to the OFF position 2. Connecting the battery charging cable a) Connect the battery charging cable to the battery b) Plug the charging wires into the DC outlet of the generator. WARNING -The battery gives off explosive gases; keep sparks, flames and cigarettes away. Provide adequate ventilation when charging or using batteries -Battery posts, terminals, and related accessories contain lead components. Wash hands after handling c) Connect the positive (red) terminal of the charging wire to the positive (+) battery terminal and negative (black) terminal of the charging wire to the negative (-) battery terminal 3. Press the start switch to RUN position 4. Press the DC breaker switch to ON position (Refer to Fig. 4.12 for HY1000Si and Fig. 4.13 for HY2000Si) 5. Start the generator 4.3: STOPPING THE GENERATOR SET For HY1000Si/HY2000Si (AC Operation) 1. Turn off the device and unplug devices from the generator receptacles 2. Press the start switch to the STOP position 3. Rotate the fuel switch to the OFF position (in the clockwise direction) NOTICE Be sure the fuel SWITCH is in the OFF position and the start switch is in the STOP position when stopping, transporting and/or storing the generator 23.