Download Spec Sheet - The Reynolds Company
Transcript
11-8 Maintenance and Troubleshooting Table 11.1: Problem or Symptom Channel BM line Troubleshooting Guide (continued) Error Code Possible Cause(s) 07 Bad connections Bad Encoder Channel AM line 08 Bad connections Bad Encoder Bus Undervoltage Bus Overvoltage 09 10 Illegal Hall State 11 RESERVED RESERVED RESERVED RESERVED RESERVED 12 13 14 15 16 Low AC line/AC power input (100 V AC minimum for safe drive operation) Excessive regeneration of power When the drive is driven by an external mechanical power source, it may regenerate too much peak energy through the drive’s power supply. The system faults to save itself from an overload. Excessive AC input voltage Output short circuit Motor cabling wires shorted together Internal motor winding short circuit Incorrect phasing Bad connections Publication 1398-5.0 – October 1998 Action/Solution Verify continuity of the encoder cable and connectors. Verify continuity of the BM+ and BM- wiring signals. Replace the motor or the encoder. Verify continuity of the encoder cable. Verify continuity of the AM+ and AM- wiring signals. Replace the motor or the encoder. Verify voltage level of the incoming VAC power. Check main VAC power source for glitches or line drop (below 90 VAC). Install an uninterruptible power supply (UPS) on your VAC input. Change the deceleration or motion profile and/or reduce the reflected inertia of your mechanical system. Use a larger system (motor and drive). Verify input is below 264 VAC. Check for shorts. Check for shorts. Check for shorts. Check the Hall phasing. Verify the Hall wiring.