Download Spec Sheet - The Reynolds Company

Transcript
11-8
Maintenance and Troubleshooting
Table 11.1:
Problem or Symptom
Channel BM line
Troubleshooting Guide (continued)
Error Code
Possible Cause(s)
07
Bad connections
Bad Encoder
Channel AM line
08
Bad connections
Bad Encoder
Bus Undervoltage
Bus Overvoltage
09
10
Illegal Hall State
11
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
12
13
14
15
16
Low AC line/AC power input
(100 V AC minimum for safe
drive operation)
Excessive regeneration of
power
When the drive is driven by
an external mechanical
power source, it may regenerate too much peak energy
through the drive’s power
supply. The system faults to
save itself from an overload.
Excessive AC input voltage
Output short circuit
Motor cabling wires shorted
together
Internal motor winding short
circuit
Incorrect phasing
Bad connections
Publication 1398-5.0 – October 1998
Action/Solution
Verify continuity of the
encoder cable and connectors.
Verify continuity of the BM+
and BM- wiring signals.
Replace the motor or the
encoder.
Verify continuity of the
encoder cable.
Verify continuity of the AM+
and AM- wiring signals.
Replace the motor or the
encoder.
Verify voltage level of the
incoming VAC power.
Check main VAC power
source for glitches or line
drop (below 90 VAC).
Install an uninterruptible
power supply (UPS) on your
VAC input.
Change the deceleration or
motion profile and/or reduce
the reflected inertia of your
mechanical system.
Use a larger system (motor
and drive).
Verify input is below 264
VAC.
Check for shorts.
Check for shorts.
Check for shorts.
Check the Hall phasing.
Verify the Hall wiring.