ProfiTrace 2 – User Manual 5.4 Network Condition Indicator The Network Condition Indicator (Overview tab) gives a general idea of the health of the PROFIBUS system. A traffic light indicates if the PROFIBUS network is OK (green), has problems but still runs (yellow) or has problems needing urgent attention (red). The overview features a summary of the most important ProfiTrace statistics. These are updated realtime. In the Network Condition Indicator Details you find warnings generated by ProfiTrace based on electrical or telegram faults. A timer shows how long the measurement has been running, and percentages next to each traffic light colour indicates how much time the network has been in that state. _______________________________________________ Version 4.3.1 – November 2013 Page 46 / 148 ProfiTrace2-Manual-EN.docx © PROCENTEC 2003-2013 - Copyright - all rights reserved