4. MAINTENANCE
4.1 CHECKLIST
These checks are to be carried out by the operator during the routine operations cycle.
4.1.1 DAILY CHECK
•
Operate prefilter drain ball valve as required to prevent excess accumulation.
This may require frequent exercise depending on line moisture content. If the
drain is automatic, check for functionality and blow down daily to remove
accumulated fluids.
•
Check the filter DPI/incident monitors. A reading in the red indicates a dirty filter
element and it should be replaced. Filter elements should last between 6 to 12
months under normal use. The must be replaced annually regardless of the
incident monitor reading.
•
Check correct purge pressure.
•
Ensure dryer is cycling without alarms.
4.1.2 WEEKLY CHECK
•
Check all mufflers for backpressure at the pressure gauge on a regenerating
chamber. It should not exceed 1 psig. Replace muffler if clogged or dirty.
•
Verify heater operation.
4.1.3 QUARTERLY CHECK (EVERY THREE MONTHS)
•
Check operating conditions, purge rate, line pressure, inlet flow.
•
Check dryer operating cycle for proper operation of valve operators, solenoid
valves, dump valves, heaters, pressure switches and temperature controller.
•
Check the outlet dewpoint.
•
Blow down relief valves.
•
Check heater outlet temperature is between 400°F and 425°F.
•
Verify pressure switch operation.
•
Inspect pilot air filter element. If element seems clogged, dirty or damaged,
replace it.