Download 3500 Process Controller HA027988_15_3500

Transcript
3500 Series Controllers
12.
User Manual
Chapter 12 Alarms
Alarms are used to alert an operator when a pre-set level has been exceeded. They are indicated by
a message in the message centre and the red ALM beacon as described in section 2.7. They may
also switch an output– usually a relay (see section 12.3.2) – to allow external devices to be operated
when an alarm occurs.
Alarms can be divided into two main types. These are Analogue and Digital Alarms:-
12.1
Analogue alarms
operate by monitoring an analogue variable such as the process variable and
comparing it with a set threshold.
Digital alarms
operate when the state of a boolean variable changes, for example, sensor
break.
Number of Alarms
up to eight analogue and eight digital alarms may be configured. Any alarm can
be enabled in the ‘Inst’ ‘Enb’ list as described in Chapter 6.
Further Alarm Definitions
Soft Alarms
are indication only and do not operate an output.
Events
are indication only but can operate an output. They can also be configured,
using the editing tool (iTools), to provide text messages on the display. For the
purpose of the configuration of this controller, alarms and events can be
considered the same.
Hysteresis
is the difference between the point at which the alarm switches ‘ON’ and the
point at which it switches ‘OFF’. It is used to provide a definite indication of the
alarm condition and to prevent alarm relay chatter.
Latching Alarm
used to hold the alarm condition once an alarm has been detected. It may be
configured as:None
Non latching
A non latching alarm will reset itself when the alarm
condition is removed
Auto
Automatic
An auto latching alarm requires acknowledgement
before it is reset. The acknowledgement can occur
BEFORE the condition causing the alarm is removed.
Manual
Manual
The alarm continues to be active until both the alarm
condition is removed AND the alarm is
acknowledged. The acknowledgement can only
occur AFTER the condition causing the alarm is
removed.
Event
Event
ALM beacon does not light but an output associated
with this parameter will activate and a scrolling
message will appear if this has been configured.
Blocking Alarms
The alarm may be masked during start up. Blocking prevents the alarm from
being activated until the process has first achieved a safe state. It is used, for
example, to ignore start up conditions which are not representative of running
conditions. A blocking alarm is re-initiated after a setpoint change.
Delay
Applies to analogue alarms. A short time can be set for each alarm which
prevents the output from going into the alarm state. The alarm is still detected as
soon as it occurs, but if it cancels before the end of the delay period then no
output is triggered. The timer for the delay is then reset. It is also reset if an
alarm is changed from being inhibited to uninhibited.
Part No HA027988
Issue 15
Jun-13
115