Download 3500 Process Controller HA027988_15_3500
Transcript
3500 Series Controllers 12. User Manual Chapter 12 Alarms Alarms are used to alert an operator when a pre-set level has been exceeded. They are indicated by a message in the message centre and the red ALM beacon as described in section 2.7. They may also switch an output– usually a relay (see section 12.3.2) – to allow external devices to be operated when an alarm occurs. Alarms can be divided into two main types. These are Analogue and Digital Alarms:- 12.1 Analogue alarms operate by monitoring an analogue variable such as the process variable and comparing it with a set threshold. Digital alarms operate when the state of a boolean variable changes, for example, sensor break. Number of Alarms up to eight analogue and eight digital alarms may be configured. Any alarm can be enabled in the ‘Inst’ ‘Enb’ list as described in Chapter 6. Further Alarm Definitions Soft Alarms are indication only and do not operate an output. Events are indication only but can operate an output. They can also be configured, using the editing tool (iTools), to provide text messages on the display. For the purpose of the configuration of this controller, alarms and events can be considered the same. Hysteresis is the difference between the point at which the alarm switches ‘ON’ and the point at which it switches ‘OFF’. It is used to provide a definite indication of the alarm condition and to prevent alarm relay chatter. Latching Alarm used to hold the alarm condition once an alarm has been detected. It may be configured as:None Non latching A non latching alarm will reset itself when the alarm condition is removed Auto Automatic An auto latching alarm requires acknowledgement before it is reset. The acknowledgement can occur BEFORE the condition causing the alarm is removed. Manual Manual The alarm continues to be active until both the alarm condition is removed AND the alarm is acknowledged. The acknowledgement can only occur AFTER the condition causing the alarm is removed. Event Event ALM beacon does not light but an output associated with this parameter will activate and a scrolling message will appear if this has been configured. Blocking Alarms The alarm may be masked during start up. Blocking prevents the alarm from being activated until the process has first achieved a safe state. It is used, for example, to ignore start up conditions which are not representative of running conditions. A blocking alarm is re-initiated after a setpoint change. Delay Applies to analogue alarms. A short time can be set for each alarm which prevents the output from going into the alarm state. The alarm is still detected as soon as it occurs, but if it cancels before the end of the delay period then no output is triggered. The timer for the delay is then reset. It is also reset if an alarm is changed from being inhibited to uninhibited. Part No HA027988 Issue 15 Jun-13 115