Download Basic characteristics data • Instruction manual
Transcript
DC-DC Converters Bus Converter . Power Module Type Table 3.2 Capacitance Values for External Output Capacitor Cout [ F] (CQHS250) Recommended capacitance Ambient temperature Ta=-40~-20C Ta=-20~0C Ta=0~+85C 470 470 220 330 100 100 Output voltage(V) 32 50 2200 1000 Recommended capacitance Maximum Base plate temperature capacitance Tc=-40~-20C Tc=-20~0C Tc=0~+100C 470X2 470X2 470 3300 330X2 330 330 2200 32 50 ¡The specified ripple and ripple noise are measured by the method introduced in Fig. 3.4 and Fig.3.5. Measuring board +S +VIN 㧗VOUT Overcurrent protection prevents the unit from short circuit and overcurrent condition. ¡The DC output will be shut down, when the output voltage drops under the output voltage adjustment range (low voltage protection). ¡Recovery from the protection is accomplished by applying 5VDC or less input for at least 1 second, or toggling remote ON / OFF signal for at least 1 second. ¡Recovery from the protection is accomplished by applying 5VDC or less input for at least 1 second, or toggling remote ON / OFF signal for at least 1 second. + + RC 0.1mF Cout Load Remarks : Please note that devices inside the power supply might fail when -VIN -VOUT CQHS ¡Overcurrent protection is built-in and comes into effect at over 105% of the rated current. ¡The overvoltage protection circuit is built-in. The DC input should be shut down if overvoltage protection is in operation. 50mm Cin 4.1 Overcurrent protection and Low voltage protection 4.2 Overvoltage protection ¿ CQHS250 DC input 4 Function Maximum capacitance Table 3.3 Capacitance Values for External Output Capacitor Cout [ F] (CQHS300/CQHS350) Output voltage(V) Instruction Manual voltage more than rated output voltage is applied to output pin of the power supply. This could happen when the customer tests the -S overvoltage performance of the unit. Oscilloscope BW㧦100MHz 1. 5m 50W Coaxial Cable R C 4.3 Thermal protection R=50W C=0.01mF ¡Over Temperature Protection (OTP) is built in. If the temperature of PCB exceed 120C (CQHS250) or the base plate temperature Fig.3.4 Method of Measuring Output Ripple and Ripple Noise (CQHS250) exceed 100C (CQHS300/CQHS350). OTP will work, causing the output voltage to drop. ¡Recovery from the protection is accomplished by applying 5VDC or less input for at least 1 second, or toggling remote ON / OFF ¿ CQHS300/CQHS350 signal for at least 1 second, after the unit should be cool down. 50mm CY Measuring board Mounting +S 4700pF hole +VIN 㧗VOUT Cout Co DC input + + Cin ¡Option ”-N” means the output voltage of the power module will be recovered automatically when the fault condition (such as OCP, + RC 0.1mF Load -VIN -VOUT -S Oscilloscope BW㧦100MHz R C 1. 5m 50W Coaxial Cable R=50W C=0.01mF Co32V㧦470mF 50V㧦220mF Fig.3.5 Method of Measuring Output Ripple and Ripple Noise (CQHS300/CQHS350) CQHS-12 ¿ -N (CQHS250) OVP or OTP) is corrected.