Table 3.2 Capacitance Values for External Output Capacitor Cout [ F]
(CQHS250)
Recommended capacitance
Ambient temperature
Ta=-40~-20C
Ta=-20~0C
Ta=0~+85C
470
470
220
330
100
100
Output
voltage(V)
32
50
2200
1000
Recommended capacitance
Maximum
Base plate temperature
capacitance
Tc=-40~-20C
Tc=-20~0C
Tc=0~+100C
470X2
470X2
470
3300
330X2
330
330
2200
32
50
¡The specified ripple and ripple noise are measured by the method
introduced in Fig. 3.4 and Fig.3.5.
Measuring board
+S
+VIN 㧗VOUT
Overcurrent protection prevents the unit from short circuit and
overcurrent condition.
¡The DC output will be shut down, when the output voltage drops
under the output voltage adjustment range (low voltage protection).
¡Recovery from the protection is accomplished by applying 5VDC
or less input for at least 1 second, or toggling remote ON / OFF
signal for at least 1 second.
¡Recovery from the protection is accomplished by applying 5VDC
or less input for at least 1 second, or toggling remote ON / OFF
signal for at least 1 second.
+
+
RC
0.1mF
Cout
Load
Remarks :
Please note that devices inside the power supply might fail when
-VIN -VOUT
CQHS
¡Overcurrent protection is built-in and comes into effect at over
105% of the rated current.
¡The overvoltage protection circuit is built-in. The DC input should
be shut down if overvoltage protection is in operation.
50mm
Cin
4.1 Overcurrent protection and Low voltage
protection
4.2 Overvoltage protection
¿ CQHS250
DC
input
4 Function
Maximum
capacitance
Table 3.3 Capacitance Values for External Output Capacitor Cout [ F]
(CQHS300/CQHS350)
Output
voltage(V)
Instruction Manual
voltage more than rated output voltage is applied to output pin of
the power supply. This could happen when the customer tests the
-S
overvoltage performance of the unit.
Oscilloscope
BW㧦100MHz
1. 5m 50W
Coaxial Cable
R
C
4.3 Thermal protection
R=50W
C=0.01mF
¡Over Temperature Protection (OTP) is built in. If the temperature
of PCB exceed 120C (CQHS250) or the base plate temperature
Fig.3.4 Method of Measuring Output Ripple and Ripple Noise
(CQHS250)
exceed 100C (CQHS300/CQHS350). OTP will work, causing the
output voltage to drop.
¡Recovery from the protection is accomplished by applying 5VDC
or less input for at least 1 second, or toggling remote ON / OFF
¿ CQHS300/CQHS350
signal for at least 1 second, after the unit should be cool down.
50mm
CY
Measuring board
Mounting +S
4700pF hole
+VIN 㧗VOUT
Cout Co
DC
input
+
+
Cin
¡Option ”-N” means the output voltage of the power module will be
recovered automatically when the fault condition (such as OCP,
+
RC
0.1mF
Load
-VIN -VOUT
-S
Oscilloscope
BW㧦100MHz
R
C
1. 5m 50W
Coaxial Cable
R=50W
C=0.01mF
Co32V㧦470mF
50V㧦220mF
Fig.3.5 Method of Measuring Output Ripple and Ripple Noise
(CQHS300/CQHS350)
CQHS-12
¿ -N (CQHS250)
OVP or OTP) is corrected.