Download Actuator with CANopen interface User manual
Transcript
Communication via CAN bus 9.13.2.14 1200h: Server SDO Parameter The COB IDs for the Default Server SDO are indicated via object 1200h (see chapter 9.3.7: Service Data Objects (SDOs)). Sub-index Description Access PDO mapping Data type Default EEPROM 00h Number of subindexes read-only no Unsigned8 2 no Sub-index Description 01h Access PDO mapping Data type Default EEPROM Sub-index Description COB-ID Master actuator (rx) read-only no Unsigned32 600h + Node-ID no 02h Access PDO mapping Data type Default EEPROM COB-ID Stellantrieb Master (tx) read-only no Unsigned32 580h + Node-ID no Format description: Bit 31 0 = SDO valid 1 = SDO not valid reserved (statically 0) 0 = 11-bit identifier (CAN 2.0A) 1 = 29-bit identifier (CAN 2.0B) if bit 29=1, bit 28 ... 11 of the 29-bit identifier 4 bit function code of the identifier 7 bit Node ID of the identifier Bit 30 Bit 29 Bit 28 - 11 Bit 10 - 7 Bit 6 - 0 Data description: The default DSO cannot be changed (according to the CiA DS-301 Predefined Connection Set). AG06 Date: 12.11.2015 Art. No. 85674 Mod. status 396/15 Page 72 of 114