Download Getting Started with Static and Kinematic Surveys GPS System 500
Transcript
Equipment checklist for Static and Rapid-Static measurements using System 500 If you want to use System 500 for Static or Rapid-Static survey then the minimum equipment you need is a pair of System 500 units. Each unit comprises a SR510 or SR520 or SR530 sensor. A single frequency SR510 sensor requires an AT501 single frequency antenna; SR520 and SR530 sensors need to be connected to a dualfrequency antenna, normally the AT502 standard antenna or - for utmost accuracy - high precision chokering antennas: either a AT503 or AT504. An antenna cable is needed to connect the sensor and the antenna. A TR500 terminal - a keyboard & display device - is needed to easily start the operation, check system status and manipulate sensor parameters. Static and Kinematic Surveys-2.0.0en 6 Batteries are needed to power the sensor. Standard are two camcorder batteries which are plugged into the backside of the sensor and power the unit for about 6 hours. 7 Warning Brand new camcorder batteries need about 5 charging cycles before reaching the full capacity. It is highly recommended to fully charge and decharge camcorder batteries for 4 to 5 times before start-ing using them for practical fieldwork. This is easily accomplished by plugging them into the sensor and having the sensor turned on until the sensor switches off automatically once the batteries get flat. Then simply recharge them and repeat this exercise. 7 Equipment checklist