Download - Eurotherm
Transcript
Configuration and adjustment variables
Modbus CANopen
Read/
Code
address address
Write
11960
2059 / 3D
rSL RW0
11908
2059 / 9
PII
R/WS
11920
2059 / 15
rPI
R/W
10001
2046 / 2
bLC
R/WS
10002
2046 / 3
brL
R/WS
10006
2046 / 7
Ibr
R/WS
10004
2046 / 5
brt
R/WS
10003
2046 / 4
bEn
R/WS
10005
2046 / 6
bEt
R/WS
10007
2046 / 8
bIP
R/WS
Name/Description/Possible values
Restart error threshold ("wake-up" threshold)
Unit: 0.1
Factory setting: 0
Adjustment range: 0 to 1000
If the "PI" and "Low speed operating time"(tLS) (see page 28) functions are configured at the
same time, the PI regulator may attempt to set a speed lower than LSP.
This results in unsatisfactory operation which consists of starting, operating at low speed then
stopping, and so on…
Parameter rSL (restart error threshold) can be used to set a minimum PI error threshold for
restarting after a stop at prolonged LSP.
The function is inactive if tLS = 0.
Internal PI reference enabled
Factory setting: 0
0 = "nO": The PI regulator reference is Fr1, except for UPdH and UPdt (+/- speed cannot be
used as the PI regulator reference).
1 = "YES": The PI regulator reference is internal via parameter rPI.
Internal PI reference
Unit: 0.1%
Factory setting: 0
Adjustment range: 0 to 1000
Brake control configuration
Factory setting: 0
Function active only if LAC = L2 or L3 (page 35).
0 = "nO": Not assigned
2 = "r2": Relay R2
64 = "dO": Logic output AOC
If bLC is assigned, parameters FLr (page 52) and brA (page 39) are forced to nO, and parameter
OPL (page 52) is forced to YES.
bLC is forced to nO if OPL = OAC (page 52).
Note This function may be incompatible with other functions (see page 14).
Brake release frequency
Unit: 0.1 Hz
Factory setting: According to drive rating
Adjustment range: 0 to 100
Motor current threshold for brake release
Unit: 0.1 A
Factory setting: According to drive rating
Adjustment range: 0 to 1.36 In (1)
(1) In corresponds to the nominal drive current indicated in the Installation Manual and on the
drive rating plate.
Brake release time
Unit: 0.01 s
Factory setting: 50
Adjustment range: 0 to 500
Brake engage frequency threshold
Unit: 0.1 Hz
Factory setting: 65535
Adjustment range: 0 to LSP
65535 = "nO": Not set
0 to LSP: Adjustment range in Hz
If bLC is assigned and bEn still equals nO, the drive will lock on a bLF detected fault on the first
run command.
Brake engage time
Unit: 0.01 s
Factory setting: 50
Adjustment range: 0 to 500
Brake release pulse
Factory setting: 0
0 = "nO": While the brake is releasing, the motor torque direction corresponds to the direction
of rotation commanded.
1 = "YES": While the brake is releasing, the motor torque direction is forward, regardless of the
direction of operation commanded.
Note: Check that the motor torque direction for "Forward" control corresponds to the upward
direction of the load. If necessary, reverse two motor phases.
BBV51701 06/2009
47