SaltiGem Status Indicator, Warnings and Safety Shutdowns
There is a STATUS indicator on the front panel that simply shows green (OK) and red
(WARNING). The reason for any WARNING will be written on the LCD display. Possible
warnings are explained below.
Low Water Temperature & Salinity
Low water temperature and lower than recommended salt levels can both cause low
conductivity of the water to be detected.
®
The SaltiGem will, however, continue to function and will display this without a red
warning indication. Simply check the salt level and make sure it is well above 3000ppm
(ideally around 4000ppm).
Check the temperature of the water, and if it is lower than 20ºC, you may wish to adjust the
Water Temperature setting using Advanced Settings Menus (information on Advanced
Settings available via www.poolcontrols.com.au or by calling Pool Controls Service on
1300 550 010.
Gas Detection & Dry-Run Pump Shutdown
®
This is an important safety feature of the SaltiGem as a build up of chlorine gas can be
dangerous.
The display above left shows the Cell being turned OFF after chlorine gas is detected for
approximately 10 seconds. If gas is still detected after approximately 2 minutes the pump
will also be turned OFF – and the display will read as shown above right.
To re-start the pump, simply press the ON-button (as instructed by the display). This will
reset the warnings and allow the pump to run (for a maximum of 3 minutes if gas is still
detected).